1SFA898210R7000 ABB PSTX142 Soft Starter, 208-690V AC, Auto

MPN1SFA898210R7000
Active

ABB PSTX142 soft starter, order code 1SFA898210R7000, 208…690 V AC, auto phase sequence detection, ramp time 1…120 s, Modbus-RTU/TCP, Ethernet/IP, EtherCAT, Profinet.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

1SFA898210R7000 key specifications
ParameterValue
Terminal typeMain Circuit: Bars
Product main typePSTX142
Voltage208 ... 690 V AC
Initial voltage during start10 ... 99 %
Step down voltage special ramp100 ... 10 %
Rated control supply voltage100 ... 250 V AC
Rated control circuit voltage24 V DC
Technical UL (CSA, maximum operating voltage UL, CSA)Main Circuit 690 V
Current limit function1.5 ... 7.5 xle
Starting capacity at maximum rated current ie4xIe for 10s
Rated operational current - In-Line connection142 A
Rated operational current - inside delta connection245 A

All specifications

1SFA898210R7000 additional specifications
ParameterValue
Technical UL (CSA, horsepower rating UL, CSA)(200 ... 208 V AC) Three Phase 40 Hp
Rated operational power - In-Line connection(230 V) 37 kW
Rated operational power - inside delta connectionat 230 V 75 kW
Rated frequency50/60 Hz
IP ratingacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
ProtocolModbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
Switch for inside delta connectionYes
Material compliance (SCIP)7ac58c93-1935-4f9a-a1cf-b53a16b37b9e Sweden
Material compliance (Simplified SCIP)2c12831e-d227-4343-89cd-8ad9d0598b61 Croatia
Popular downloads (CAD dimensional drawing)2CDC001079B0201
Material compliance (Toxic substances control act - TSCA)2CMT2023-006524
Material compliance (Conflict minerals reporting template)9AKK108467A5658
Technical UL (CSA, tightening torque UL, CSA)Main Circuit 123.9
FunctionAuto phase sequence detection
Ramp time1 ... 120 second [unit of time]
Analog outputs0...10 V, 0...20 mA, 4...20 mA
Warning detailsCurrent imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Run signal relayYes
Tightening torqueMain Circuit 14 N·m
Fault signal relayYes
Overload protectionBuilt-in electronic overload protection
Protection functionBypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
By-pass signal relayYes
Overload signal relayYes
Ambient air temperatureOperation -25 ... +60 °C
Service factor percentage100 %
Object classification codeQ
Popular downloads (EPLAN data)9AAC181166_EPLAN
Signal indication faultRed
Integrated electronic overloadYes
Connecting capacity main circuitHole Diameter 8.5 mm
Signal indication running rGreen
Connecting capacity supply circuitRigid 1 x 2.5
IDEA granular category code4740 >> Soft starter
Signal indication protectionYellow
Connecting capacity control circuitRigid 1 x 2.5 mm²
Popular downloads (Instructions and manuals)1SFC132428M0201
Popular downloads (Data sheet, technical information)1SFC132012C0201
Popular Downloads/Instructions and manuals (Part 2)1SFC132081M0201
Popular Downloads/Instructions and manuals (Part 3)1SFC132060M0201

Product details

The ABB PSTX142 (1SFA898210R7000) is a soft starter with built-in auto phase sequence detection — it verifies the incoming phase rotation before the motor starts, so you don't risk a reverse-spinning conveyor or pump on commissioning. Ramp time is adjustable from 1 to 120 seconds, which lets you tune the acceleration for the load — a loaded crusher needs a longer ramp than a light fan. The control circuit runs on 24 V DC; the main control supply accepts 100…250 V AC, so the logic stays isolated from the power stage.

Communications and integration

This unit speaks Modbus-RTU, Modbus-TCP, Ethernet/IP, EtherCAT, DeviceNet, CANopen, Profibus, Profinet, BACnet-IP, and BACnet-MSTP — essentially every fieldbus you'll find in a modern panel. That means the PSTX142 drops into a greenfield EtherCAT line or a legacy Profibus installation without a gateway. The main circuit terminals are bars; torque them to 14 N·m. Analog outputs are configurable as 0…10 V, 0…20 mA, or 4…20 mA, so you can feed a speed reference or current signal to a PLC analog card directly.

Protection and diagnostics

Electronic overload protection is built in — no separate overload relay needed. The protection suite covers current imbalance, underload, earth fault, locked rotor, over/under voltage, phase reversal, PTC/PT-100 motor thermal inputs, and a user-defined protection set. That's a lot of ground fault and thermal coverage without external modules. Warning outputs flag 15 conditions including faulty fan, EOL, thyristor overload, and THD(U). Separate signal relays for run, fault, bypass, and overload give discrete status back to the controller. LED indicators on the front (green run, red fault, yellow protection) let a technician read the state at a glance.

Frequently asked questions

Where can I buy 1SFA898210R7000 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What does auto phase sequence detection mean on this soft starter?

It checks the incoming phase rotation (-L2-L3 order) before the motor starts and will not energize if the sequence is reversed, preventing a motor from running backward. This is a built-in function, not an add-on module.

What is the ramp time range on the PSTX142?

The ramp time is adjustable from 1 to 120 seconds, letting you match the acceleration profile to the load inertia — short for low-inertia fans, long for high-inertia conveyors or crushers.