ABB 1SFA898210R7000

1SFA898210R7000 ABB PSTX142 Soft Starter, 208-690V AC, Auto

MPN 1SFA898210R7000
Active

ABB PSTX142 soft starter, order code 1SFA898210R7000, 208…690 V AC, auto phase sequence detection, ramp time 1…120 s, Modbus-RTU/TCP, Ethernet/IP, EtherCAT, Profinet.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

1SFA898210R7000 specifications
ParameterValue
Terminal typeMain Circuit: Bars
Voltage208 ... 690 V AC
Frequency50/60 Hz
Temp operating max60 °C
Temp operating min-25 °C

Product details

The ABB PSTX142 (1SFA898210R7000) is a soft starter with built-in auto phase sequence detection — it verifies the incoming phase rotation before the motor starts, so you don't risk a reverse-spinning conveyor or pump on commissioning. Ramp time is adjustable from 1 to 120 seconds, which lets you tune the acceleration for the load — a loaded crusher needs a longer ramp than a light fan. The control circuit runs on 24 V DC; the main control supply accepts 100…250 V AC, so the logic stays isolated from the power stage.

Communications and integration

This unit speaks Modbus-RTU, Modbus-TCP, Ethernet/IP, EtherCAT, DeviceNet, CANopen, Profibus, Profinet, BACnet-IP, and BACnet-MSTP — essentially every fieldbus you'll find in a modern panel. That means the PSTX142 drops into a greenfield EtherCAT line or a legacy Profibus installation without a gateway. The main circuit terminals are bars; torque them to 14 N·m. Analog outputs are configurable as 0…10 V, 0…20 mA, or 4…20 mA, so you can feed a speed reference or current signal to a PLC analog card directly.

Protection and diagnostics

Electronic overload protection is built in — no separate overload relay needed. The protection suite covers current imbalance, underload, earth fault, locked rotor, over/under voltage, phase reversal, PTC/PT-100 motor thermal inputs, and a user-defined protection set. That's a lot of ground fault and thermal coverage without external modules. Warning outputs flag 15 conditions including faulty fan, EOL, thyristor overload, and THD(U). Separate signal relays for run, fault, bypass, and overload give discrete status back to the controller. LED indicators on the front (green run, red fault, yellow protection) let a technician read the state at a glance.

MPN
1SFA898210R7000