ABB 1SFA898218R7000 — Soft Starters

ABB 1SFA898218R7000 PSTX720 Soft Starter, 720 A

MPN1SFA898218R7000
Active

ABB PSTX720 soft starter, 1SFA898218R7000, 720 A, 208–690 V AC, 50/60 Hz, auto phase sequence detection, ramp time 1–120 s, Modbus-RTU/TCP, Ethernet/IP, EtherCAT, Profibus, Profinet, DeviceNet, CANopen, BACnet-IP/MSTP, main circuit bars, IP00 terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

1SFA898218R7000 key specifications
ParameterValue
Terminal typeMain Circuit: Bars
Product main typePSTX720
Voltage208 ... 690 V AC
Initial voltage during start10 ... 99 %
Step down voltage special ramp100 ... 10 %
Rated control supply voltage100 ... 250 V AC
Rated control circuit voltage24 V DC
Technical UL (CSA, maximum operating voltage UL, CSA)Main Circuit 690 V
Current limit function1.5 ... 7.5 xle
Starting capacity at maximum rated current ie4xIe for 10s
Rated operational current - In-Line connection720 A
Rated operational current - inside delta connection1247 A

All specifications

1SFA898218R7000 additional specifications
ParameterValue
Technical UL (CSA, horsepower rating UL, CSA)(200 ... 208 V AC) Three Phase 250 Hp
Rated operational power - In-Line connection(230 V) 200 kW
Rated operational power - inside delta connectionat 230 V 355 kW
Rated frequency50/60 Hz
IP ratingacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
ProtocolModbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
Switch for inside delta connectionYes
Popular downloads (CAD dimensional drawing)2CDC001079B0201
Material compliance (Toxic substances control act - TSCA)2CMT2023-006524
Material compliance (Conflict minerals reporting template)9AKK108467A5658
Technical UL (CSA, tightening torque UL, CSA)Main Circuit 398.3
FunctionAuto phase sequence detection
Ramp time1 ... 120 second [unit of time]
Analog outputs0...10 V, 0...20 mA, 4...20 mA
Warning detailsCurrent imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Run signal relayYes
Tightening torqueMain Circuit 45 N·m
Fault signal relayYes
Overload protectionBuilt-in electronic overload protection
Protection functionBypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
By-pass signal relayYes
Overload signal relayYes
Ambient air temperatureOperation -25 ... +60 °C
Service factor percentage100 %
Object classification codeQ
Popular downloads (EPLAN data)9AAC185673_EPLAN
Signal indication faultRed
Integrated electronic overloadYes
Signal indication running rGreen
Connecting capacity supply circuitRigid 1 x 2.5
IDEA granular category code4740 >> Soft starter
Signal indication protectionYellow
Connecting capacity control circuitRigid 1 x 2.5 mm²
Popular downloads (Instructions and manuals)1SFC132428M0201
Popular downloads (Data sheet, technical information)1SFC132012C0201
Popular Downloads/Instructions and manuals (Part 2)1SFC132081M0201
Popular Downloads/Instructions and manuals (Part 3)1SFC132060M0201

Product details

PSTX720 — what fits on the line side

The ABB PSTX720 (1SFA898218R7000) is a 720 A soft starter for three-phase induction motors on 208–690 V AC supplies, 50/60 Hz. Auto phase sequence detection is baked in — it checks rotation before the ramp starts, saving a contactor and a callout on pump or conveyor direction. Ramp time is adjustable from 1 to 120 seconds, with initial voltage from 10 to 99 % and a step-down special ramp from 100 to 10 % for soft stop. Current limit function spans 1.5 to 7.5 x Ie. Fieldbus coverage is wide: Modbus-RTU, Modbus-TCP, Ethernet/IP, EtherCAT, DeviceNet, CANopen, Profibus, Profinet, BACnet-IP, and BACnet-MSTP. That list covers most PLC backbones without an extra gateway. Analog outputs are configurable as 0–10 V, 0–20 mA, or 4–20 mA for drive feedback to a VFD or SCADA input card.

Protection and signalling — what trips and what tells you

Built-in electronic overload protection with separate overload curves for start and run (dual overload). Protection functions include ground fault, earth fault, phase reversal, locked rotor, under/over voltage, current imbalance/underload, PTC connection, too-long start time, and too-long current limit. Warning outputs mirror most of these — current imbalance, underload, electronic overload time-to-trip, EOL, faulty fan, locked rotor, motor runtime limit, over/under voltage, phase loss (standby), power factor underload, short circuit (limp mode), THD(U), thyristor overload, and voltage imbalance. Four signal relays are standard — run, fault, bypass, and overload — each with a dedicated LED on the front panel (green for run, red for fault, yellow for protection). The control circuit runs on 24 V DC; the control supply accepts 100–250 V AC. Main circuit terminals are bars with a tightening torque of 45 N·m; control circuit connections accept rigid 1 x 2.5 mm² wire.

Ambient operating temperature is -25 to +60 °C. Main terminals are IP00 per IEC 60529 and IEC 60947-1 — open bus bars, so the panel enclosure provides the ingress protection. The unit supports inside-delta connection for reduced cable sizing on the motor side. Service factor is rated at 100 %.

Frequently asked questions

Does ABB PSTX720 (1SFA898218R7000) support Modbus TCP and Ethernet/IP?

Yes — the communication list includes Modbus-RTU, Modbus-TCP, Ethernet/IP, EtherCAT, DeviceNet, CANopen, Profibus, Profinet, BACnet-IP, and BACnet-MSTP. No external gateway required for any of these protocols.

What is 1SFA898218R7000's listed ramp time?

The ramp time is adjustable from 1 to 120 seconds. Initial voltage during start can be set from 10 to 99 %, and the step-down special ramp (soft stop) from 100 to 10 %.

What is the difference between ABB PSTX720 and PSTX370?

The PSTX720 is rated for 720 A, while the PSTX370 is rated for 370 A. Both share the same family features — auto phase sequence detection, the same fieldbus options, and the same protection set. The choice is driven by motor full-load current: the 720 A unit handles larger motors, typically above 370 A FLC.

MPN
1SFA898218R7000