ABB 1SFA898218R7000

ABB 1SFA898218R7000 PSTX720 Soft Starter, 720 A

MPN 1SFA898218R7000
Active

ABB PSTX720 soft starter, 1SFA898218R7000, 720 A, 208–690 V AC, 50/60 Hz, auto phase sequence detection, ramp time 1–120 s, Modbus-RTU/TCP, Ethernet/IP, EtherCAT, Profibus, Profinet, DeviceNet, CANopen, BACnet-IP/MSTP, main circuit bars, IP00 terminals.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

1SFA898218R7000 specifications
ParameterValue
Terminal typeMain Circuit: Bars
Voltage208 ... 690 V AC
Frequency50/60 Hz
Temp operating max60 °C
Temp operating min-25 °C

Product details

PSTX720 — what fits on the line side

The ABB PSTX720 (1SFA898218R7000) is a 720 A soft starter for three-phase induction motors on 208–690 V AC supplies, 50/60 Hz. Auto phase sequence detection is baked in — it checks rotation before the ramp starts, saving a contactor and a callout on pump or conveyor direction. Ramp time is adjustable from 1 to 120 seconds, with initial voltage from 10 to 99 % and a step-down special ramp from 100 to 10 % for soft stop. Current limit function spans 1.5 to 7.5 x Ie. Fieldbus coverage is wide: Modbus-RTU, Modbus-TCP, Ethernet/IP, EtherCAT, DeviceNet, CANopen, Profibus, Profinet, BACnet-IP, and BACnet-MSTP. That list covers most PLC backbones without an extra gateway. Analog outputs are configurable as 0–10 V, 0–20 mA, or 4–20 mA for drive feedback to a VFD or SCADA input card.

Protection and signalling — what trips and what tells you

Built-in electronic overload protection with separate overload curves for start and run (dual overload). Protection functions include ground fault, earth fault, phase reversal, locked rotor, under/over voltage, current imbalance/underload, PTC connection, too-long start time, and too-long current limit. Warning outputs mirror most of these — current imbalance, underload, electronic overload time-to-trip, EOL, faulty fan, locked rotor, motor runtime limit, over/under voltage, phase loss (standby), power factor underload, short circuit (limp mode), THD(U), thyristor overload, and voltage imbalance. Four signal relays are standard — run, fault, bypass, and overload — each with a dedicated LED on the front panel (green for run, red for fault, yellow for protection). The control circuit runs on 24 V DC; the control supply accepts 100–250 V AC. Main circuit terminals are bars with a tightening torque of 45 N·m; control circuit connections accept rigid 1 x 2.5 mm² wire.

Ambient operating temperature is -25 to +60 °C. Main terminals are IP00 per IEC 60529 and IEC 60947-1 — open bus bars, so the panel enclosure provides the ingress protection. The unit supports inside-delta connection for reduced cable sizing on the motor side. Service factor is rated at 100 %.

MPN
1SFA898218R7000