ABB 3ABD00037852-D — Inverter / VFD

ABB 3ABD00037852-D ACS880-01 drive, 30 kW, 52 A, R4

MPN3ABD00037852-D
Active

ABB ACS880-01, 3ABD00037852-D, wall-mounted single drive, 30 kW / 52 A normal duty, 22 kW / 40 A heavy duty, frame R4, IP21, 380–500 VAC, 47.5–63 Hz.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3ABD00037852-D specifications
ParameterValue
MountingWall-mounted
Enclosure type NEMAType1
Input voltage380 ... 500 V
Output current, normal use52 A
Output current, Heavy-Duty use40 A
Output current, Light-Overload use49 A
Output power, normal use30 kW
Output power, Heavy-Duty use22 kW
Output power, Light-Overload use30 kW
Frequency47.5 ... 63 Hz
Phases3-phase
IP ratingIP21
Frame sizeR4
Efficiency levelIE2

Product details

The ABB 3ABD00037852-D is an ACS880-01 wall-mounted single drive rated 30 kW normal use (52 A output) and 22 kW heavy-duty use (40 A output) — the heavy-duty figure is the one to size against if the load profile includes frequent starts or short-term overloads. Frame size R4, IP21 enclosure, NEMA Type 1. Input accepts three-phase 380–500 V at 47.5–63 Hz. Efficiency class IE2.

The heavy-duty current rating (40 A) is the more restrictive number for motor starting; normal-use rating (52 A) applies to constant-torque loads with moderate overload.

Frequently asked questions

What is the frame size of 3ABD00037852-D?

Frame size R4.

What is the input voltage and frequency range?

Three-phase 380–500 V, 47.5–63 Hz.

What are the normal and heavy-duty output ratings?

Normal use: 30 kW, 52 A. Heavy-duty use: 22 kW, 40 A.

MPN