Skip to main content
ABB 1SFA896114R7000

ABB 1SFA896114R7000 PSR85 Softstarter, 600 V

MPN1SFA896114R7000
Active

ABB PSR85 soft starter, voltage ramp with 0–20 s ramp time, 208–600 V AC operational, 100–240 V AC control supply, order code 1SFA896114R7000.

$909.00Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

1SFA896114R7000 key specifications
ParameterValue
Terminal typeMain Circuit: Bars
Product main typePSR85
Voltage208 ... 600 V AC
Initial voltage during start40 ... 70 %
Step down voltage special ramp100 ... 60 %
Rated control supply voltage100 ... 240 V AC
Rated control circuit voltage24 V DC
Technical UL (CSA, maximum operating voltage UL, CSA)Main Circuit 600 V
Current limit functionNo
Starting capacity at maximum rated current ie4xIe for 6s
Rated operational current - In-Line connection85 A
Technical UL (CSA, horsepower rating UL, CSA)(200 ... 208 V AC) Three Phase 25 Hp
All specifications+32
1SFA896114R7000 additional specifications
ParameterValue
Rated operational power - In-Line connection(230 V) 22 kW
Rated frequency50/60 Hz
IP ratingacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
ProtocolFiledBusPlug(Optional)
Switch for inside delta connectionNo
Popular downloads (CAD dimensional drawing)2CDC001079B0201
Material compliance (Toxic substances control act - TSCA)2CMT2023-006524
Material compliance (Conflict minerals reporting template)9AKK108467A5658
Technical UL (CSA, tightening torque UL, CSA)Control Circuit 5.3 in·lb
FunctionSoft start with voltage ramp
Ramp time0 ... 20 second [unit of time]
Run signal relayYes
Tightening torqueControl Circuit 0.6 N·m
Fault signal relayNo
Overload protectionRecommended MS495 70 ... 90
By-pass signal relayYes
Overload signal relayNo
Ambient air temperatureOperation -25 ... +60 °C
Service factor percentage100 %
Object classification codeQ
Popular downloads (EPLAN data)9AAC157494_EPLAN
Integrated electronic overloadNo
Connecting capacity main circuitRigid 1x 10 ... 95 mm²
Signal indication running rGreen
Connecting capacity supply circuitRigid 1 x 0.75 ... 2.5
IDEA granular category code4740 >> Soft starter
Connecting capacity control circuit1 x 0.75 ... 2.5 mm²
Signal indication ramping up (Down)Green
Popular downloads (Instructions and manuals)1SFC132033M0001
Signal indication completed start rampGreen
Popular downloads (Data sheet, technical information)1SFC132012C0201
Popular Downloads/Instructions and manuals (Part 3)1SFC132060M0201

Product details

The ABB 1SFA896114R7000 is a PSR85-class soft starter that ramps motor voltage from an adjustable initial level to full line, sized for a 208–600 V AC operational envelope and a starting capacity of 4xIe for 6s at maximum rated current Ie. It is a voltage-ramp unit, not a current-limit device: the current-limit function is absent, and overload protection is specified externally as the ABB MS495 70…90 thermal overload.

Ramp profile and what the integrator sets

Ramp time spans 0…20 s, the initial voltage during start is adjustable from 40…70 %, and a step-down special ramp covers 100…60 %, so soft-stop behavior is configurable on the same ramp setting rather than as a separate parameter.

Control wiring and supply

Main circuit uses bars with rigid cable capacity 1x 10…95 mm²; the supply and control terminal blocks accept 1 x 0.75…2.5 mm² rigid conductors.

Status outputs the field tech sees

Run signal relay, bypass signal relay, and three green LEDs (running R, ramping up/down, completed start ramp) provide the local status picture; fault signal and overload signal relays are not present, so those conditions must be read via the optional FieldBusPlug or external wiring.

Environment and compliance

Operation is rated -25…+60 °C ambient at 50/60 Hz, main terminals carry IP10 per IEC 60529 / IEC 60947-1, and the part is RoHS-compliant under EU Directive 2011/65/EU with Amendment 2015/863 dated July 22, 2019.

Sourcing posture

No lifecycle status entry is carried on this order code, so production status should be confirmed against current ABB PSR85 line information before committing the BOM; quoted against an RFQ to the usual ABB soft-starter channel, with the optional FieldBusPlug and the MS495 70…90 external overload specified as separate line items if the application needs bus connectivity or motor thermal protection.

Frequently asked questions

What is the listed function of the 1SFA896114R7000?

Soft start with voltage ramp — a voltage-ramp soft starter, not a current-limit device, rated for 208…600 V AC operation.

What is the ramp time on the 1SFA896114R7000?

Ramp time is 0…20 s, with an initial voltage during start of 40…70 % and a step-down special ramp of 100…60 %.

Does the 1SFA896114R7000 have built-in overload protection?

No integrated electronic overload is provided; ABB specifies the external MS495 70…90 thermal overload for motor protection on this unit.

What compliance documentation does ABB provide for the 1SFA896114R7000?

The part is declared RoHS-compliant under EU Directive 2011/65/EU and Amendment 2015/863 dated July 22, 2019, and carries an IP10 main-terminal rating to IEC 60529 / IEC 60947-1.

MPN
1SFA896114R7000