Heavy-duty rating of 55 kW (96 A) handles higher starting torque for crushers or extruders. Light-overload rating is 75 kW (118 A). Input voltage range 380-500 V covers common 400 V and 480 V networks, 47.5-63 Hz. IP21 enclosure is suitable for indoor panel or wall mounting; NEMA Type 1 equivalent.
3ABD00038188-D ABB ACS880-01-124A-5+E202 75 kW Drive, Frame
MPN3ABD00038188-D
Active
ABB ACS880-01-124A-5+E202, 75 kW (124 A) normal-duty, 55 kW (96 A) heavy-duty, 380-500 V, 3-phase, IP21, frame R6, IE2.
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →Specifications
Electrical
| Parameter | Value |
|---|---|
| Input voltage | 380 ... 500 V |
| Frequency | 47.5 ... 63 Hz |
| Number of phases | 3-phase |
Power & Current
| Parameter | Value |
|---|---|
| Output power, normal duty | 75 kW |
| Output power, heavy duty | 55 kW |
| Output power, light-overload duty | 75 kW |
| Output current, heavy duty | 96 A |
| Output current, normal duty | 124 A |
| Output current, light-overload duty | 118 A |
| Efficiency class (IE) | IE2 |
Protection & Environmental
| Parameter | Value |
|---|---|
| Degree of protection (IP) | IP21 |
| NEMA enclosure type | Type1 |
Mechanical
| Parameter | Value |
|---|---|
| Frame size | R6 |
| Mounting type | Wall-mounted |
Product details
Frequently asked questions
What are the key ratings for this drive?
Normal use: 75 kW, 124 A. Heavy-duty use: 55 kW, 96 A. Light-overload use: 75 kW, 118 A. Input voltage 380-500 V, 3-phase, 47.5-63 Hz. Frame size R6, IP21 enclosure.
What is the frame size of this drive?
Frame size R6.
What is the input frequency range?
47.5 to 63 Hz.
MPN
3ABD00038188-D
