Skip to main content
ABB 3ABD00038222-D — Inverter / VFD

ABB 3ABD00038222-D ACS880-01 Drive, 75 kW, 124 A, Frame R6

MPN3ABD00038222-D
Active

ABB ACS880-01, 3ABD00038222-D, LV AC industrial wall-mounted single drive, 75 kW / 124 A, frame size R6.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3ABD00038222-D specifications
ParameterValue
MountingWall-mounted
Enclosure type NEMAType1
Input voltage380 ... 500 V
Output current, normal use124 A
Output current, Heavy-Duty use96 A
Output current, Light-Overload use118 A
Output power, normal use75 kW
Output power, Heavy-Duty use55 kW
Output power, Light-Overload use75 kW
Frequency47.5 ... 63 Hz
Phases3-phase
IP ratingIP21
Frame sizeR6
Efficiency levelIE2

Product details

The ABB 3ABD00038222-D is a wall-mounted single drive rated for 75 kW normal-use output at 124 A, with a heavy-duty rating of 55 kW at 96 A. It runs on 380–500 V three-phase input, 47.5–63 Hz, and lands in frame size R6. The IP21 enclosure and NEMA Type 1 rating cover indoor installations where some dust and dripping water are present.

Three duty curves are listed: normal use (Pn 75 kW, In 124 A), heavy-duty (PhD 55 kW, IhD 96 A), and light-overload (PlD 75 kW, IlD 118 A). For a constant-torque application like a conveyor or extruder, the heavy-duty figure governs — 55 kW is the continuous rating. For variable-torque loads such as fans and pumps, the normal-use 75 kW applies. The light-overload number (118 A) sits between the two; it typically covers short-duration overload profiles.

Integration notes

Wall-mounted, frame R6. Efficiency class IE2 is standard for this generation. The WEEE category (Large Equipment, >50 cm) affects end-of-life disposal planning in EU markets.

Frequently asked questions

What is the frame size of this drive?

Frame size R6.

What input voltage and frequency does it accept?

380–500 V three-phase, 47.5–63 Hz.

What is the normal-use output rating?

75 kW at 124 A.

What is the heavy-duty output rating?

55 kW at 96 A.

MPN