The 3ABD00038226-D: Three duty points are listed: normal-use (Pn 160 kW, In 260 A), heavy-duty (PhD 132 kW, IhD 240 A), and light-overload (PlD 160 kW, IlD 247 A). The heavy-duty figure governs continuous motor load applications like conveyors or pumps; the normal-use rating applies to variable-torque loads such as fans. Light-overload sits between the two at 247 A, useful for occasional peak demands without stepping up a frame.
Wall-mounted, frame size R8. IP21 protection and NEMA Type 1 enclosure suit indoor installation in clean environments. The WEEE category (4, Large Equipment) confirms dimensions over 50 cm — plan for adequate wall support and lifting points during installation.