Skip to main content
ABB 3ABD00038227-D — AC Drives (VFD)

ABB 3ABD00038227-D ACS880-01 Drive, 200 kW, 361 A, Frame R9

MPN3ABD00038227-D
Active

ABB ACS880-01 wall-mounted single drive, 3ABD00038227-D, frame size R9, 200 kW / 361 A normal-use output, 380–500 V 3-phase input, IP21, NEMA 1, IE2 efficiency.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Electrical

3ABD00038227-D — Electrical
ParameterValue
Input voltage380 ... 500 V
Frequency47.5 ... 63 Hz
Number of phases3-phase

Power & Current

3ABD00038227-D — Power & Current
ParameterValue
Output power, normal duty200 kW
Output power, heavy duty160 kW
Output power, light-overload duty200 kW
Output current, heavy duty302 A
Output current, normal duty361 A
Output current, light-overload duty343 A
Efficiency class (IE)IE2

Protection & Environmental

3ABD00038227-D — Protection & Environmental
ParameterValue
Degree of protection (IP)IP21
NEMA enclosure typeType1

Mechanical

3ABD00038227-D — Mechanical
ParameterValue
Frame sizeR9
Mounting typeWall-mounted

Product details

The ABB 3ABD00038227-D is an ACS880-01 wall-mounted single drive rated for 200 kW normal-use output at 361 A, with a heavy-duty rating of 160 kW at 302 A. Input is 380–500 V three-phase, 47.5–63 Hz, and the enclosure is IP21 / NEMA Type 1. Frame size R9. Efficiency class IE2.

Normal-use (Pn 200 kW, In 361 A) covers constant-torque loads like conveyors and pumps at full rating. Heavy-duty (PhD 160 kW, IhD 302 A) applies for higher starting torque or cyclic overloads — a 20 % current margin over the heavy-duty figure ensures the drive handles the peak without tripping.

Wall-mounted, frame R9. IP21 protects against solid objects over 12 mm and dripping water; NEMA Type 1 is equivalent for indoor use. The enclosure is sized for the 200 kW output — expect a substantial footprint and gland-plate entry for the incoming supply and motor cables.

Frequently asked questions

What are the key ratings for this drive?

Normal-use output is 200 kW at 361 A; heavy-duty output is 160 kW at 302 A. Input voltage is 380–500 V three-phase, 47.5–63 Hz. Frame size R9, IP21/NEMA 1 enclosure, IE2 efficiency.

What is the frame size?

Frame size R9.

What is the input frequency range?

47.5 to 63 Hz.

MPN