ABB 3ABD00039381-D ACS880-04 Drive Module, 880 A, 630 kW

MPN3ABD00039381-D
Active

ABB ACS880-04 LV AC single drive module, 3ABD00039381-D, 630 kW / 880 A normal use, 380-500 V 3-phase, IP20, frame size R11.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3ABD00039381-D specifications
ParameterValue
MountingModule
Enclosure type NEMAOpen Type
Input voltage380 ... 500 V
Output current, normal use880 A
Output current, Heavy-Duty use697 A
Output current, Light-Overload use857 A
Output power, normal use630 kW
Output power, Heavy-Duty use500 kW
Output power, Light-Overload use560 kW
Frequency47.5 ... 63 Hz
Phases3-phase
IP ratingIP20
Frame sizeR11

Product details

Drive module for high-power motor control

The ABB 3ABD00039381-D is an LV AC industrial single drive module rated for 630 kW normal-use output at 880 A, with heavy-duty capability at 500 kW / 697 A and light-overload at 560 kW / 857 A. It accepts 380-500 V three-phase input across 47.5-63 Hz and is enclosed to IP20 in frame size R11.

Rating selection for duty cycle

Three output ratings let you match the module to the load profile. Normal-use 880 A covers continuous constant-torque applications. Heavy-duty 697 A applies for high-starting-torque or cyclic loads where the drive must deliver peak current without tripping. Light-overload 857 A sits between — useful for pumps and fans with moderate transient demand.

Frame R11 is an open-type module (NEMA Open Type) for cabinet mounting. IP20 allows direct access to terminals inside a locked enclosure. Frequency tolerance 47.5-63 Hz handles weak mains or generator supply.

Frequently asked questions

What is the frame size of this drive module?

Frame size R11. This is a large cabinet-mount module; the open-type NEMA enclosure requires installation in a suitable electrical enclosure.

What are the output ratings for normal, heavy-duty, and light-overload use?

Normal use: 630 kW / 880 A. Heavy-duty: 500 kW / 697 A. Light-overload: 560 kW / 857 A.