The 3ABD00058101-D: The 2.6 A normal-use output current (0.75 kW) matches a standard 0.75 kW induction motor. Light-overload duty is rated 2.5 A. Input voltage covers 380…500 V three-phase at 47.5…63 Hz. The IP20 open-type enclosure is intended for a clean, dry panel.
Wall-mounted, frame R1 — compact enough for small machine cabinets. The open-type NEMA rating (no enclosure) means the installer provides the surrounding panel protection.