Skip to main content
ABB 3ABD00059522-D — Inverter / VFD

ABB 3ABD00059522-D ACS880-01 Drive, 4 kW, 7.6 A, Frame R1

MPN3ABD00059522-D
Active

ABB ACS880-01 series, LV AC industrial wall-mounted single drive, 4 kW / 7.6 A normal duty, 380-500 V 3-phase, IP21, NEMA Type 1, Frame R1, IE2.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3ABD00059522-D specifications
ParameterValue
MountingWall-mounted
Enclosure type NEMAType1
Input voltage380 ... 500 V
Output current, normal use7.6 A
Output current, Heavy-Duty use5.2 A
Output current, Light-Overload use7.2 A
Output power, normal use4 kW
Output power, Heavy-Duty use3.0 kW
Output power, Light-Overload use4.0 kW
Frequency47.5 ... 63 Hz
Phases3-phase
IP ratingIP21
Frame sizeR1
Efficiency levelIE2

Product details

The ABB 3ABD00059522-D is a wall-mounted drive rated 4 kW normal duty, 7.6 A output, on a 380-500 V three-phase supply. Frame size R1. IP21 and NEMA Type 1 enclosure.

Three duty points are listed, and picking the right one decides whether the drive survives the application. Normal-use output is 4 kW at 7.6 A — that is the continuous rating for a standard variable-torque load like a fan or centrifugal pump. Heavy-duty use drops to 3.0 kW at 5.2 A, which is the rating to use for constant-torque loads, conveyors, or applications with short-term overloads. Light-overload use sits at 4.0 kW at 7.2 A, a middle ground for applications with occasional peak demands. Sizing against the wrong duty class is the most common mistake on this drive family.

Supply and frequency flexibility

Input voltage range of 380-500 V three-phase. Frequency acceptance from 47.5 to 63 Hz.

Efficiency and enclosure

Rated IE2 efficiency meets the baseline level for EU motor-driven systems under current regulations. The IP21 / NEMA Type 1 enclosure is the standard indoor protection level — no special washdown or dust sealing, so plan the cabinet environment accordingly.

Frequently asked questions

What is the frame size of this drive?

The frame size is R1, which defines the mechanical footprint and mounting hole pattern for panel layout.

What are the normal-duty and heavy-duty ratings?

Normal duty is 4 kW at 7.6 A output. Heavy-duty rating is 3.0 kW at 5.2 A output. Light-overload rating is 4.0 kW at 7.2 A.

MPN
3ABD00059522-D