Skip to main content
ABB 3ABD00059722-D — Inverter / VFD

ABB 3ABD00059722-D ACS880-04 Drive Module, 400 kW, 583 A

MPN3ABD00059722-D
Active

ABB ACS880-04 single drive module, 400 kW normal use, 583 A output, 380–500 V input, frame R10, IP20, active production.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3ABD00059722-D specifications
ParameterValue
MountingModule
Enclosure type NEMAOpen Type
Input voltage380 ... 500 V
Output current, normal use583 A
Output current, Heavy-Duty use414 A
Output current, Light-Overload use573 A
Output power, normal use400 kW
Output power, Heavy-Duty use250 kW
Output power, Light-Overload use400 kW
Frequency48 ... 63 Hz
Phases3-phase
IP ratingIP20
Frame sizeR10

Product details

ABB 3ABD00059722-D is an LV AC industrial single drive module with position control, rated for 400 kW normal-use output at 583 A on a 380–500 V three-phase supply. Frame size R10, IP20 open-type enclosure.

The normal-use output of 400 kW / 583 A applies to variable-torque loads — centrifugal pumps, fans, compressors where torque rises with speed. The light-overload figure of 573 A sits just below the normal-use current, so the drive handles short-duration overloads without stepping down a frame.

Frequently asked questions

What is the frame size of 3ABD00059722-D?

The frame size is R10, which defines the mechanical dimensions and busbar spacing for cabinet integration.

What input voltage and frequency does this drive accept?

Input voltage range is 380–500 V AC, three-phase, at 48–63 Hz.

What are the normal-use and heavy-duty output ratings?

Normal-use (variable torque): 400 kW, 583 A. Heavy-duty (constant torque): 250 kW, 414 A.

MPN
3ABD00059722-D