Skip to main content
ABB 3ABD00059726-D — Inverter / VFD

ABB 3ABD00059726-D ACS880 Drive Module, 630 kW, 880 A

MPN3ABD00059726-D
Active

ABB ACS880-04 series, LV AC industrial single drive module with position control, 3-phase, 380...500 V, 48...63 Hz, frame size R11, NEMA Open Type, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3ABD00059726-D specifications
ParameterValue
MountingModule
Enclosure type NEMAOpen Type
Input voltage380 ... 500 V
Output current, normal use880 A
Output current, Heavy-Duty use697 A
Output current, Light-Overload use857 A
Output power, normal use630 kW
Output power, Heavy-Duty use500 kW
Output power, Light-Overload use560 kW
Frequency48 ... 63 Hz
Phases3-phase
IP ratingIP20
Frame sizeR11

Product details

It runs on a 380...500 V three-phase supply, 48...63 Hz, in an IP20 open-type enclosure, frame size R11.

Duty ratings that define the fit

Heavy-duty (PhD) drops to 500 kW / 697 A, which governs constant-torque applications such as conveyors or extruders where the drive must hold rated torque across the speed range. Light-overload (PlD) sits at 560 kW / 857 A, a middle band for applications with moderate overload profiles. Matching the duty class to the load profile is what keeps the drive out of thermal trip during peak demand.

This module carries an active product status, so it remains in ABB's current production portfolio.

Frame and mechanical fit

Frame size R11 defines the mechanical footprint and bus-bar interface. The module mounts as a drop-in unit within the R11-compatible cabinet infrastructure; verify the existing backplane and DC-link buswork match this frame before ordering.

Frequently asked questions

What is the frame size of the 3ABD00059726-D?

The frame size is R11, which determines its physical dimensions and bus-bar interface within the ACS880-04 platform.

What duty ratings does the 3ABD00059726-D carry?

Normal-use: 630 kW / 880 A. Heavy-duty: 500 kW / 697 A. Light-overload: 560 kW / 857 A. Choose the rating that matches your load profile.

How do I source the 3ABD00059726-D?

It is an active ABB part. Submit an RFQ with your BOM line, and we will quote to order.

MPN
3ABD00059726-D