Duty ratings and derating
The 3ABD50000039036: Normal-use output is 3 kW at 7.2 A. Light-overload use (variable-torque, e.g. centrifugal pumps) matches the normal-use power at 3 kW but current is capped at 6.8 A. That spread tells you the thermal headroom: the drive is sized for pump/fan duty, but if your load profile is hard on the IGBTs, stay inside the heavy-duty line.
Rated IE2 efficiency class. The WEEE category is 'Product Not in WEEE Scope', so end-of-life disposal follows local waste regulations for industrial equipment rather than the WEEE directive.