Skip to main content
ABB 3ABD50000039038 — Inverter / VFD

ABB 3ABD50000039038 ACQ580-01 Drive, 5.5 kW, 12.6 A, IP55

MPN3ABD50000039038
Active

ABB ACQ580-01 wall-mounted drive, frame size R1, 5.5 kW/12.6 A normal duty, IP55, IE2, 3-phase 380-500 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3ABD50000039038 specifications
ParameterValue
MountingWall-mounted
Enclosure type NEMAType12
Input voltage380 ... 500 V
Output current, normal use12.6 A
Output current, Heavy-Duty use9.4 A
Output current, Light-Overload use12 A
Output power, normal use5.5 kW
Output power, Heavy-Duty use4 kW
Output power, Light-Overload use5.5 kW
Frequency47.5 ... 63 Hz
Phases3-phase
IP ratingIP55
Frame sizeR1
Efficiency levelIE2

Product details

The ABB 3ABD50000039038 is an ACQ580-01 wall-mounted drive sized for water and wastewater applications. Frame size R1, rated 5.5 kW normal use at 12.6 A, with a heavy-duty curve of 4 kW at 9.4 A. Input accepts 380...500 V three-phase at 47.5...63 Hz. IP55 enclosure, IE2 efficiency, NEMA Type 12.

The normal-use rating (12.6 A, 5.5 kW) covers continuous pump or fan loads at rated current. The heavy-duty rating (9.4 A, 4 kW) applies when the drive must handle higher peak torque or constant-torque loads like screw feeders or positive-displacement pumps — the lower current reflects the thermal headroom needed for overload cycles. Light-overload use (12 A, 5.5 kW) is essentially the normal curve with a slightly trimmed current limit for applications that rarely hit full load.

Physical and mounting

Wall-mounted, frame R1. IP55 and NEMA Type 12 enclosure suit the drive for washdown areas or dusty environments — no additional cabinet is required for indoor use. The 3-phase input is 380...500 V; verify supply voltage matches the drive's input range before wiring.

Frequently asked questions

What are the key electrical ratings?

Normal use: 5.5 kW at 12.6 A. Heavy-duty: 4 kW at 9.4 A. Input: 380...500 V three-phase, 47.5...63 Hz. Output frequency range matches the input frequency band.

What enclosure protection does it have?

IP55 and NEMA Type 12. Suitable for indoor environments with dust or water spray — no additional enclosure needed for most installations.

MPN