Skip to main content
ABB 3ABD50000039046 — Inverter / VFD

ABB 3ABD50000039046 ACQ580-01 VFD, 15 kW, 32 A, IP55

MPN3ABD50000039046
Active

ABB ACQ580-01 wall-mounted LV AC drive, 3-phase 380-500 V, 15 kW / 32 A normal duty, IP55, NEMA Type 12, Frame R3.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3ABD50000039046 specifications
ParameterValue
MountingWall-mounted
Enclosure type NEMAType12
Input voltage380 ... 500 V
Output current, normal use32 A
Output current, Heavy-Duty use24.6 A
Output current, Light-Overload use30.4 A
Output power, normal use15 kW
Output power, Heavy-Duty use11 kW
Output power, Light-Overload use15 kW
Frequency47.5 ... 63 Hz
Phases3-phase
IP ratingIP55
Frame sizeR3
Efficiency levelIE2

Product details

The ABB 3ABD50000039046 is an ACQ580-01 wall-mounted drive rated 15 kW normal-duty output at 32 A, with heavy-duty capability at 11 kW / 24.6 A. Input accepts 380–500 V three-phase, 47.5–63 Hz. Enclosure is IP55 / NEMA Type 12, suited for washdown or dusty environments. Frame size R3.

Normal-duty (Pn) is 15 kW at 32 A; light-overload (PlD) matches at 15 kW but draws 30.4 A. Heavy-duty (PhD) drops to 11 kW at 24.6 A. For a pump or fan with constant torque, size off the normal-duty column. For a conveyor with occasional peak load, the heavy-duty figure governs thermal capacity.

Wall-mounted, IP55 / NEMA Type 12. Suitable for indoor or sheltered outdoor installation where hose-down or dust ingress is a concern. Frame R3 footprint fits the standard ACQ580-01 dimensional envelope.

Frequently asked questions

What is the frame size of this drive?

Frame size is R3.

What are the normal-duty and heavy-duty output ratings?

Normal-duty output is 15 kW at 32 A; heavy-duty output is 11 kW at 24.6 A. Light-overload rating is 15 kW at 30.4 A.

What is the input voltage and frequency range?

Input voltage is 380–500 V three-phase, 47.5–63 Hz.

What enclosure protection does it have?

IP55 / NEMA Type 12, suitable for washdown and dusty environments.

MPN
3ABD50000039046