Skip to main content
ABB 3ABD50000039048 — Inverter / VFD

ABB 3ABD50000039048 ACQ580-01 VFD, 22 kW, 45 A, IP55

MPN3ABD50000039048
Active

ABB ACQ580-01 wall-mounted LV AC drive, 3-phase, 380-500 V, 22 kW / 45 A normal duty, IP55, NEMA Type 12, Frame Size R3.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3ABD50000039048 specifications
ParameterValue
MountingWall-mounted
Enclosure type NEMAType12
Input voltage380 ... 500 V
Output current, normal use45 A
Output current, Heavy-Duty use37.7 A
Output current, Light-Overload use42.8 A
Output power, normal use22 kW
Output power, Heavy-Duty use18.5 kW
Output power, Light-Overload use22 kW
Frequency47.5 ... 63 Hz
Phases3-phase
IP ratingIP55
Frame sizeR3
Efficiency levelIE2

Product details

The ABB 3ABD50000039048 is an ACQ580-01 wall-mounted LV AC drive rated for 22 kW normal-duty output at 45 A, with a heavy-duty rating of 18.5 kW at 37.7 A. Input accepts 380-500 V three-phase, 47.5-63 Hz. Enclosure is IP55 / NEMA Type 12, so it handles washdown areas and dusty panels without a separate cabinet. Frame size R3 keeps the footprint manageable for a 22 kW unit.

The normal-duty current of 45 A is the number to match against your motor FLA for continuous applications like pumps and fans. Heavy-duty current of 37.7 A covers constant-torque loads such as conveyors or screw feeders — that's the rating that governs if your application calls for 150% overload for 60 seconds. IE2 efficiency level means the drive meets the base EU efficiency class; no premium IE3 label, but for water/wastewater duty where the pump curve rarely runs at full load, the difference is marginal.

Wall-mounted, IP55, NEMA Type 12 — gland plate entry for the conduit runs. Frame R3 has a standard mounting pattern; verify clearance for the heat sink fins on the back.

Frequently asked questions

What is the frame size of this drive?

Frame size R3.

What enclosure protection does it have?

IP55 and NEMA Type 12, suitable for indoor use in dusty or wet environments without an extra cabinet.

MPN
3ABD50000039048