The 3AXD50000047499: The 7.6 A normal-use output current is the number to match against your motor's full-load amps. Light-overload (7.2 A) covers variable-torque fans and centrifugal pumps. Ambient temperature max is +55 °C, with derating above 40 °C typical for this class. Standby loss runs 40 W; full-load power consumption is 219 W. Sound level is 57 dB(A) — quiet enough for a small machine room but not silent.
Integration notes
The drive includes a control unit. Two analog inputs and two analog outputs are available; six digital inputs and two digital outputs. Communication is via CAN — no onboard Industrial Ethernet. Altitude rating 4000 m. Operating humidity 5–95% non-condensing. R3 frame wall-mounted; IP21 enclosure. Internal lithium coin cell (CR2032, 220 mAh, 3 V, two pieces) backs up RTC and parameter storage.