Skip to main content
ABB 3AXD50000145799 — AC Drives (VFD)

3AXD50000145799 ABB ACS880-17-0420A-5 250 kW, 420 A, 380-500

MPN3AXD50000145799
Active

ABB ACS880-17 series regenerative drive, 3AXD50000145799, 250 kW normal-use output at 420 A, 380-500 VAC 3-phase input, IP22, NEMA 1, R8i+R8i frame.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3AXD50000145799 — Electrical
ParameterValue
Input voltage380 ... 500 V
Frequency48 ... 63 Hz
Number of phases3-phase
3AXD50000145799 — Power & Current
ParameterValue
Output power, normal duty250 kW
Output power, heavy duty200 kW
Output power, light-overload duty250 kW
Output current, heavy duty314 A
Output current, normal duty420 A
Output current, light-overload duty403 A
3AXD50000145799 — Protection & Environmental
ParameterValue
Degree of protection (IP)IP22
NEMA enclosure typeType1
3AXD50000145799 — Mechanical
ParameterValue
Frame sizeR8i+R8i

Product details

Drive rating at a glance

The ABB 3AXD50000145799 is an ACS880-17-0420A-5 regenerative drive rated 250 kW normal-use output (420 A continuous) on a 380-500 VAC three-phase supply. Heavy-duty use drops to 200 kW / 314 A; light-overload use holds at 250 kW / 403 A. The UL side mirrors these currents at 350 Hp normal, 250 Hp heavy-duty, and 300 Hp light-overload. Apparent power sits at 364 kV·A.

What the frame and enclosure tell you

The R8i+R8i frame is a two-cabinet build — one for the supply unit, one for the inverter. IP22 with NEMA 1 means it's indoor-rated, splash-resistant, but not hose-down. Ambient max is 40 °C; derate above that or above 1000 m altitude. The 75 dB(A) sound level is loud enough that ear protection is worth planning for in a quiet control room.

I/O and communications

Four analog inputs and four analog outputs are onboard. Digital I/O counts 14 inputs and 10 outputs. Communication is CAN-based — no onboard Industrial Ethernet, so a fieldbus adapter module is needed for PROFINET or EtherNet/IP. The control unit is included in the delivery.

Frequently asked questions

What is the SCIP number for this drive?

The SCIP number is 944D8A5E-036D-404E-9036-0D3C1EA703AD, registered in Finland.

What is the maximum operating altitude?

The drive is rated for a maximum altitude of 1000 m without derating.

What are the key power ratings?

Normal use: 250 kW / 420 A. Heavy-duty use: 200 kW / 314 A. Light-overload use: 250 kW / 403 A. Input voltage: 380-500 VAC, 3-phase, 48-63 Hz.

What enclosure protection does it have?

IP22 with NEMA Type 1. Indoor use, splash-resistant, not suitable for washdown environments.

MPN
3AXD50000145799