Skip to main content
ABB 3AXD50000145812 — Inverter / VFD

3AXD50000145812 ABB ACS880-17-0780A-5 drive, 560 kW, 780 A

MPN3AXD50000145812
Active

ABB ACS880-17 series regenerative drive, order code 3AXD50000145812, 560 kW normal-use power, 780 A output, IP22, NEMA 1.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000145812 key specifications
ParameterValue
Enclosure type NEMAType1
Input voltage380 ... 500 V
Output current, normal use780 A
Output current, Heavy-Duty use583 A
Output current, Light-Overload use749 A
Technical UL (Output current, normal use)780 A
Technical UL (Output current, Heavy-Duty use)583 A
Technical UL (Output current, Light-Overload use)749 A
Power factor1
Apparent power output676 kV·A
Output power, normal use560 kW
Output power, Heavy-Duty use400 kW

All specifications

3AXD50000145812 additional specifications
ParameterValue
Output power, Light-Overload use500 kW
Technical UL (Output power, normal use)700 Hp
Technical UL (Output power, Heavy-Duty use)500 Hp
Technical UL (Output power, Light-Overload use)600 Hp
Frequency48 ... 63 Hz
Phases3-phase
IP ratingIP22
ProtocolCAN
Number of hardware interfacesIndustrial Ethernet 0
Altitude1000 m
Operating humidity (RHamβ)5 ... 95
Frame sizeR8i+R8i
SCIP944D8A5E-036D-404E-9036-0D3C1EA703AD Finland
IncludesControl unit
Sound75 dB(A)
Analog inputs4
Analog outputs4
Temperature ratingMaximum 40 °C
Ecodesign exemptionEnergy efficiency data is not provided for the drive. The regenerative drives are exempt from the EU ecodesign requirements (Regulation EU/2019/1781, §2.3.c).
Multiple battery informationLithium Coin, BR2032, 2pcs, 3V, 200mAh, 3g
Number of digital in (Outputs)14 / 10

Product details

Drive ratings and duty selection

The 3AXD50000145812 is a regenerative drive delivering 560 kW normal-use output (780 A) on a 380–500 V three-phase supply (48–63 Hz). Heavy-duty use is rated 400 kW (583 A), light-overload use 500 kW (749 A). Apparent power output is 676 kVA.

Rated for maximum 40 °C ambient, 1000 m altitude, 5–95 % humidity. Enclosure is IP22 / NEMA Type 1. Frame size R8i+R8i. Sound pressure level 75 dB(A).

Includes 4 analog inputs, 4 analog outputs, 14 digital inputs, 10 digital outputs. Communication protocol is CAN; no Industrial Ethernet interface on this variant. Includes a control unit.

SCIP number 944D8A5E-036D-404E-9036-0D3C1EA703AD Finland. WEEE category 4 (Large Equipment >50 cm). Contains two BR2032 lithium coin cells (3 V, 200 mAh each). Exempt from EU ecodesign requirements (Regulation EU/2019/1781, §2.3.c) as a regenerative drive.

Frequently asked questions

What are the key output ratings?

Normal-use output is 560 kW / 780 A; heavy-duty is 400 kW / 583 A; light-overload is 500 kW / 749 A. Apparent power is 676 kVA.

What is the input voltage and frequency range?

380–500 V, 48–63 Hz, three-phase.

What enclosure protection does it have?

IP22 and NEMA Type 1.

What is the SCIP number?

944D8A5E-036D-404E-9036-0D3C1EA703AD Finland.

MPN
3AXD50000145812