Skip to main content
ABB 3AXD50000145867 — Inverter / VFD

ABB 3AXD50000145867 ACS880-17 Drive, 1600 kW, 2270 A

MPN3AXD50000145867
Active

ABB ACS880-17 series, regenerative drive, order code 3AXD50000145867, 1600 kW normal use, 2270 A output, 380-500 V 3-phase.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000145867 key specifications
ParameterValue
Enclosure type NEMAType1
Input voltage380 ... 500 V
Output current, normal use2270 A
Output current, Heavy-Duty use1698 A
Output current, Light-Overload use2179 A
Technical UL (Output current, normal use)2270 A
Technical UL (Output current, Heavy-Duty use)1698 A
Technical UL (Output current, Light-Overload use)2179 A
Power factor1
Apparent power output1966 kV·A
Output power, normal use1600 kW
Output power, Heavy-Duty use1200 kW

All specifications

3AXD50000145867 additional specifications
ParameterValue
Output power, Light-Overload use1500 kW
Technical UL (Output power, normal use)2000 Hp
Technical UL (Output power, Heavy-Duty use)1500 Hp
Technical UL (Output power, Light-Overload use)1900 Hp
Frequency48 ... 63 Hz
Phases3-phase
IP ratingIP22
ProtocolCAN
Number of hardware interfacesIndustrial Ethernet 0
Altitude1000 m
Operating humidity (RHamβ)5 ... 95
Frame size3xR8i+3xR8i
SCIP944D8A5E-036D-404E-9036-0D3C1EA703AD Finland
IncludesControl unit
Sound78 dB(A)
Analog inputs4
Analog outputs4
Temperature ratingMaximum 40 °C
Ecodesign exemptionEnergy efficiency data is not provided for the drive. The regenerative drives are exempt from the EU ecodesign requirements (Regulation EU/2019/1781, §2.3.c).
Multiple battery informationLithium Coin, BR2032, 2pcs, 3V, 200mAh, 3g
Number of digital in (Outputs)14 / 10

Product details

The ABB 3AXD50000145867 is a regenerative drive rated for 1600 kW normal-use output at 2270 A, fed from a 380-500 V 3-phase supply. It is built in a 3xR8i+3xR8i frame with NEMA 1 enclosure and IP22 protection. The drive carries three distinct duty ratings: 1600 kW / 2270 A for normal use, 1500 kW / 2179 A for light-overload, and 1200 kW / 1698 A for heavy-duty. The heavy-duty figure governs continuous motor torque at high starting loads or demanding cycles; the light-overload rating covers applications with occasional peak demand above the normal curve.

Duty ratings and real-world fit

The light-overload figure (1500 kW) sits between them and matches applications like pumps or fans where occasional peak demand is the exception, not the rule.

Environmental limits and installation constraints

Rated for a maximum ambient of 40 °C, altitude up to 1000 m without derating, and operating humidity of 5-95% non-condensing. The 78 dB(A) sound level at full load means hearing protection is advisable in the drive room. The regenerative design is exempt from EU ecodesign efficiency reporting (Regulation EU/2019/1781, §2.3.c) — no energy-efficiency class to declare.

I/O and communication summary

The drive includes 14 digital I/O (10 outputs), 4 analog inputs, and 4 analog outputs. Communication is via CAN bus; no onboard Industrial Ethernet. The control unit is included. Two lithium coin cells (BR2032, 3 V, 200 mAh each) back up the real-time clock and parameter storage.

Frequently asked questions

What are the key electrical ratings?

Normal-use output is 1600 kW at 2270 A; heavy-duty is 1200 kW at 1698 A; light-overload is 1500 kW at 2179 A. Input is 380-500 V 3-phase, 48-63 Hz.

What enclosure and protection rating does it have?

NEMA Type 1 enclosure with IP22 degree of protection — indoor use, no washdown capability.

What is the SCIP number for this drive?

SCIP: 944D8A5E-036D-404E-9036-0D3C1EA703AD, registered in Finland.

MPN
3AXD50000145867