Skip to main content
ABB 3AXD50000158010 — AC Drives (VFD)

ABB 3AXD50000158010 ACS880-17 Drive, 55 kW, 101 A

MPN3AXD50000158010
Active

ABB ACS880-17 regenerative drive, 55 kW / 101 A, 380-500 VAC 3-phase, Frame R8, IP22, CAN.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3AXD50000158010 — Electrical
ParameterValue
Input voltage380 ... 500 V
Frequency48 ... 63 Hz
Number of phases3-phase
3AXD50000158010 — Power & Current
ParameterValue
Output power, normal duty55 kW
Output power, heavy duty45 kW
Output power, light-overload duty55 kW
Output current, heavy duty77 A
Output current, normal duty101 A
Output current, light-overload duty91 A
3AXD50000158010 — Protection & Environmental
ParameterValue
Degree of protection (IP)IP22
NEMA enclosure typeType1
3AXD50000158010 — Mechanical
ParameterValue
Frame sizeR8

Product details

The 3AXD50000158010: Three duty points are listed. Normal-use (Pn) delivers 55 kW / 101 A — that's the continuous rating for typical variable-torque loads like pumps and fans. Heavy-duty (PhD) drops to 45 kW / 77 A, which is the constant-torque rating for conveyors or extruders where you need full torque at low speed. Light-overload (PlD) matches the normal-use power at 55 kW but current is capped at 91 A — a lighter thermal curve for applications with infrequent overloads. The UL heavy-duty rating is 60 Hp / 77 A, and the UL light-overload is 75 Hp / 96 A. Match your motor nameplate to the duty class that fits your load profile, not just the highest kW number.

This is a current-production drive. The SCIP number (82D82DAE-9725-4373-865D-AA949B97DE50 Finland) is on file for EU substance compliance tracking.

Integration notes

CAN is the onboard communication protocol — no Industrial Ethernet on this variant, so plan for a gateway if you need PROFINET or EtherNet/IP. The drive includes a control unit. Two analog inputs and two analog outputs are available; digital I/O counts seven inputs and five outputs. Ambient temperature is limited to 40 °C maximum, altitude to 1000 m without derating. Humidity range is 5-95% RH. Sound pressure at 70 dB(A) — noticeable in a quiet control room, fine on a plant floor. The regenerative design is exempt from EU ecodesign efficiency reporting (Regulation EU/2019/1781, §2.3.c).

Frequently asked questions

What are the key power ratings for this drive?

Normal-use output is 55 kW / 101 A. Heavy-duty output is 45 kW / 77 A. Light-overload output is 55 kW / 91 A. UL heavy-duty is 60 Hp / 77 A; UL light-overload is 75 Hp / 96 A.

What is the SCIP number for this drive?

The SCIP number is 82D82DAE-9725-4373-865D-AA949B97DE50 Finland.

What communication protocol does this drive use?

CAN is the onboard communication protocol. No Industrial Ethernet interface is included.

MPN