Skip to main content
ABB 3AXD50000158119 — Inverter / VFD

ABB 3AXD50000158119 ACS880-37 Drive, 90 kW, 156 A

MPN3AXD50000158119
Active

ABB ACS880-37 series drive, order code 3AXD50000158119, 90 kW normal-use power, 156 A normal-use current, 380...500 V 3-phase input.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000158119 key specifications
ParameterValue
Enclosure type NEMAType1
Input voltage380 ... 500 V
Output current, normal use156 A
Output current, Heavy-Duty use124 A
Output current, Light-Overload use148 A
Technical UL (Output current, normal use)- A
Technical UL (Output current, Heavy-Duty use)124 A
Technical UL (Output current, Light-Overload use)156 A
Power factor1
Apparent power output135 kV·A
Output power, normal use90 kW
Output power, Heavy-Duty use75 kW

All specifications

3AXD50000158119 additional specifications
ParameterValue
Output power, Light-Overload use90 kW
Technical UL (Output power, normal use)- Hp
Technical UL (Output power, Heavy-Duty use)100 Hp
Technical UL (Output power, Light-Overload use)125 Hp
Frequency48 ... 63 Hz
Phases3-phase
IP ratingIP22
ProtocolCAN
Number of hardware interfacesIndustrial Ethernet 0
Altitude1000 m
Operating humidity (RHamβ)5 ... 95
Frame sizeR8
SCIP9ECED1FE-316A-4BF4-991E-2606BB5FE13A Finland
IncludesControl unit
Sound70 dB(A)
Analog inputs2
Analog outputs2
Temperature ratingMaximum 40 °C
Ecodesign exemptionEnergy efficiency data is not provided for the drive. The low-harmonic drives are exempt from the EU ecodesign requirements (Regulation EU/2019/1781, §2.3.d).
Multiple battery informationLithium Coin, CR2032, 2pcs, 3V, 220mAh, 6g
Number of digital in (Outputs)7 / 5

Product details

The ABB 3AXD50000158119 is an ACS880-37-0156A-5 low-harmonic drive rated for 90 kW normal-use output (Pn) and 156 A normal-use current (In) on a 380...500 V three-phase supply. Heavy-duty use (PhD) is 75 kW with 124 A output (IhD); light-overload use (PlD) stays at 90 kW but draws 148 A (IlD). Apparent power output is 135 kV·A, which helps size the upstream transformer or generator. Frame size R8 sets the panel cutout and mounting footprint.

Heavy-duty vs normal-use headroom

The heavy-duty current (124 A) is lower than the normal-use current (156 A). The UL listing for heavy-duty use (100 Hp, 124 A) matches the IEC heavy-duty rating.

Integration notes

Enclosure is NEMA Type 1 with IP22 protection — suitable for indoor, non-condensing environments. Ambient temperature limit is 40 °C; altitude ceiling is 1000 m. Onboard communication is CAN — no Industrial Ethernet port. Digital I/O: 7 inputs, 5 outputs. Analog I/O: 2 inputs, 2 outputs. The control unit is included. Sound level is 70 dB(A) — factor that into panel layout if the drive sits near operator stations. The SCIP number (9ECED1FE-316A-4BF4-991E-2606BB5FE13A) is registered in Finland.

Frequently asked questions

What are the key ratings for this drive?

Normal-use output is 90 kW at 156 A; heavy-duty output is 75 kW at 124 A. Input is 380–500 V three-phase, 48–63 Hz. Apparent power rating is 135 kV·A.

What enclosure protection does it have?

The drive carries NEMA Type 1 and IP22 ratings, making it suitable for indoor installations where dripping water or falling dirt is unlikely.

What communication protocols are onboard?

The drive includes CAN communication. It has no Industrial Ethernet interface.

What is the SCIP number and where is it registered?

The SCIP number is 9ECED1FE-316A-4BF4-991E-2606BB5FE13A, registered in Finland.

MPN
3AXD50000158119