Skip to main content
ABB 3AXD50000199570 — Inverter / VFD

ABB 3AXD50000199570 Drive Module, 160 kW, 260 A, Frame R11

MPN3AXD50000199570
Active

ABB drive module, frame size R11, 3-phase, 380…500 VAC input, 160 kW normal-use / 132 kW heavy-duty output, 260 A / 240 A, IP20, Open Type.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000199570 key specifications
ParameterValue
MountingModule
Enclosure type NEMAOpen Type
Input voltage380 ... 500 V
Output current, normal use260 A
Output current, Heavy-Duty use240 A
Output current, Light-Overload use247 A
Technical UL (Output current, Heavy-Duty use)240 A
Technical UL (Output current, Light-Overload use)260 A
Power factor1.0
Apparent power output225 kV·A
Power consumption (@Pcons)3771 W
Output power, normal use160 kW

All specifications

3AXD50000199570 additional specifications
ParameterValue
Output power, Heavy-Duty use132 kW
Output power, Light-Overload use160 kW
Technical UL (Output power, Heavy-Duty use)200 Hp
Technical UL (Output power, Light-Overload use)200 Hp
Frequency47.5 ... 63 Hz
Phases3-phase
IP ratingIP20
ProtocolCAN
Number of hardware interfacesIndustrial Ethernet 0
Altitude4000 m
Operating humidity (RHamβ)5 ... 95
Frame sizeR11
Certificates and declarations (RoHS date)20240508
Certificates and declarations (REACH date)20250905
Certificates and declarations (REACH information)True - contains substances > 0.1 mass percentage
SCIP83d552bf-c84f-4f10-872c-27d3d0b10da5 Finland
IncludesControl unit
Sound75 dB(A)
Standby loss243 W
Analog inputs2
Analog outputs2
Efficiency levelIE2
Temperature ratingMaximum +55 °C
Ecodesign exemptionEnergy efficiency data is not provided for the drive. The regenerative drives are exempt from the EU ecodesign requirements (Regulation EU/2019/1781, §2.3.c).
Multiple battery informationLithium Coin, CR2032, 220 mAh, 3 V, 2 pcs, 6 g
Number of digital in (Outputs)6 / 2

Product details

The ABB 3AXD50000199570 is a drive module in frame size R11, rated for 160 kW normal-use (Pn) and 132 kW heavy-duty (PhD) output on a 3-phase 380…500 VAC supply. Normal-use output current is 260 A (In); heavy-duty drops to 240 A (IhD). Apparent power output is 225 kV·A, and the module carries an IE2 efficiency level. It is exempt from EU ecodesign efficiency reporting under Regulation EU/2019/1781 §2.3.c because regenerative drives fall outside the scope.

The 260 A normal-use rating (In) governs continuous motor current at 160 kW; the 240 A heavy-duty figure (IhD) applies when the drive must deliver 132 kW under higher overload cycles — for example, a conveyor starting under load or a crusher with intermittent torque spikes. The 225 kV·A apparent power output tells you the transformer or upstream feeder must be sized for that kVA, not just the kW. Input voltage range is 380…500 VAC at 47.5…63 Hz, covering 400 V and 480 V nominal grids common in European and North American industrial plants. Maximum ambient temperature is +55 °C, so the drive can live in a non-air-conditioned electrical room or a hot machine cabinet as long as airflow is adequate. Altitude rating goes to 4000 m, which is useful for installations at high elevation where air density drops and cooling efficiency decreases. No derating calculation is needed up to that ceiling.

WEEE category is 4 (Large Equipment), meaning end-of-life disposal follows the rules for equipment with any external dimension over 50 cm. The module includes two CR2032 lithium coin cells (220 mAh, 3 V each) for backup — these are replaceable and must be handled per local battery recycling regulations. UL technical data lists heavy-duty output at 200 Hp (240 A) and light-overload at 200 Hp (247 A), confirming the drive carries UL listing for North American installations.

Integration notes

Frame size R11 is a substantial module — expect to mount it on a backplate or inside a floor-standing cabinet, not on a DIN rail. The IP20 rating means all live parts are finger-safe but not protected against water or dust ingress, so the cabinet must provide the environmental seal. Standby loss is 243 W, which contributes to the cabinet's thermal load; factor that into your cooling calculation. The module has 2 analog inputs and 2 analog outputs for speed reference or process feedback, plus 6 digital inputs and 2 digital outputs. Communication is via CAN protocol — no onboard Industrial Ethernet, so if your control network is PROFINET or EtherNet/IP, you will need an external gateway or option module. Sound pressure level is 75 dB(A) — noticeable in a quiet electrical room but typical for a drive of this power class. The 3771 W power consumption at rated load (Pcons) is the real power drawn from the supply, including losses; use this figure for sizing upstream contactors and fuses, not just the output kW.

Frequently asked questions

Where can I buy 3AXD50000199570 and how do I get a price?

This drive module is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is 3AXD50000199570's listed SCIP number?

The SCIP number is 83d552bf-c84f-4f10-872c-27d3d0b10da5, registered in Finland. This is the article identifier for waste reporting under the EU Waste Framework Directive.

What compliance documentation does ABB provide for 3AXD50000199570?

RoHS compliance follows EU Directive 2011/65/EU and Amendment 2015/863 (compliance date 2024-05-08). REACH declaration confirms substances above 0.1 mass percentage (declaration date 2025-09-05). UL technical data is also available for North American installations.

What is the altitude rating of 3AXD50000199570?

The drive is rated for installation at altitudes up to 4000 m without derating, which covers high-elevation sites such as mining operations or mountain-based processing plants.

MPN