Specifications

3AXD50000222612 key specifications
ParameterValue
MountingModule
Enclosure type NEMAOpen Type
Input voltage380 ... 500 V
Output current, normal use302 A
Output current, Heavy-Duty use260 A
Output current, Light-Overload use302 A
Technical UL (Output current, Heavy-Duty use)260 A
Technical UL (Output current, Light-Overload use)302 A
Power factor1.0
Apparent power output262 kV·A
Power consumption (@Pcons)4773 W
Output power, normal use160 kW

All specifications

3AXD50000222612 additional specifications
ParameterValue
Output power, Heavy-Duty use132 kW
Output power, Light-Overload use160 kW
Technical UL (Output power, Heavy-Duty use)200 Hp
Technical UL (Output power, Light-Overload use)250 Hp
Frequency47.5 ... 63 Hz
Phases3-phase
IP ratingIP20
ProtocolCAN
Number of hardware interfacesIndustrial Ethernet 0
Altitude4000 m
Operating humidity (RHamβ)5 ... 95
Frame sizeR11
Certificates and declarations (RoHS date)20240508
Certificates and declarations (REACH date)20250320
Certificates and declarations (REACH information)True - contains substances > 0.1 mass percentage
IncludesControl unit
Sound75 dB(A)
Standby loss243 W
Analog inputs2
Analog outputs2
Efficiency levelIE2
Temperature ratingMaximum +55 °C
Ecodesign exemptionEnergy efficiency data is not provided for the drive. The regenerative drives are exempt from the EU ecodesign requirements (Regulation EU/2019/1781, §2.3.c).
Multiple battery informationLithium Coin, CR2032, 220 mAh, 3 V, 2 pcs, 6 g
Number of digital in (Outputs)6 / 2

Product details

Duty ratings that matter

The 3AXD50000222612: Normal-use (light-overload) output is 160 kW / 302 A; heavy-duty use drops to 132 kW / 260 A. Apparent power output is 262 kV·A, which gives you a quick check against transformer sizing.

Installation constraints

IP20 open-type enclosure, so it's panel-mount only — no floor-standing without an enclosure. Ambient max is +55 °C, altitude rated to 4000 m without derating. Standby loss is 243 W, which matters for cabinet cooling calcs. Sound level is 75 dB(A) — noticeable in a small room, plan ear protection if it's near a workstation.

Communications and I/O

Includes a control unit with 2 analog inputs, 2 analog outputs, 6 digital inputs, and 2 digital outputs. Communication is CAN-based — no onboard Ethernet.

Sourcing note

Active lifecycle stage — no end-of-life notice.

Frequently asked questions

What are the key output ratings for this drive?

Normal-use output is 160 kW at 302 A; heavy-duty use is 132 kW at 260 A. Light-overload use matches normal-use at 160 kW / 302 A.

What is the altitude rating for the 3AXD50000222612?

Rated for operation up to 4000 m altitude without derating.

Does this drive include a control unit?

Yes, the drive includes a control unit with 2 analog inputs, 2 analog outputs, 6 digital inputs, and 2 digital outputs.

MPN