ABB 3AXD50000507924 ACH580-34 Drive Module, 361 A, 300 Hp

MPN3AXD50000507924
Active

ABB 3AXD50000507924, ACH580-34 series, LV AC ultra-low harmonic drive module, Frame Size R11, 361 A light-overload (UL), 300 Hp light-overload (UL), 302 A heavy-duty (UL), 250 Hp heavy-duty (UL), 47.5–63 Hz.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000507924 specifications
ParameterValue
MountingModule
Technical UL (Output current, Heavy-Duty use)302 A
Technical UL (Output current, Light-Overload use)361 A
Technical UL (Output power, Heavy-Duty use)250 Hp
Technical UL (Output power, Light-Overload use)300 Hp
Frequency47.5 ... 63 Hz
Frame sizeR11

Product details

The ABB 3AXD50000507924 is an ACH580-34 ultra-low harmonic drive module, sized for HVAC applications that need to stay inside IEEE 519 current distortion limits without an external filter. Frame size R11 is the mechanical envelope — expect a module roughly the footprint of a small panel cabinet, not a standalone drive with integrated controls. The 361 A light-overload rating (UL) covers the bulk of 300 Hp fan and pump loads at 480 V; the heavy-duty curve drops to 302 A / 250 Hp for constant-torque conveyors or compressors where the duty cycle demands more thermal headroom. Frequency range of 47.5 to 63 Hz means it handles both 50 Hz and 60 Hz line supplies without derating.

The two UL current ratings define the application envelope. Light-overload at 361 A is the number for variable-torque loads — most centrifugal fans and pumps — where the motor rarely pulls full current for more than a few seconds at start. Heavy-duty at 302 A applies when the load is constant-torque (positive-displacement pumps, conveyors, crushers) or when the drive must deliver rated current continuously without a service factor. If your BOM specifies a 300 Hp motor on a fan, the 361 A light-overload rating is the one that confirms fit; if the same motor drives a screw compressor, the heavy-duty 302 A rating is the binding constraint.

Integration note

This is a drive module, not a standalone drive — it mounts inside an ABB cabinet or a custom panel and requires a separate control unit (typically the ACH580-34 control panel or a fieldbus adapter). The frame size R11 determines the bus bar spacing and the DC-link bushing layout; verify the mechanical interface against the cabinet cutout before panel design. The ultra-low harmonic topology uses a 12-pulse or active front-end rectifier, so the line-side reactor and DC-link choke are already integrated — no external harmonic filter needed for most applications.

Frequently asked questions

What is the frame size of 3AXD50000507924?

Frame size R11. This determines the physical mounting footprint, bus bar spacing, and DC-link bushing layout for panel integration.

What compliance documentation is available for this part?

The module carries a WEEE Category 4 classification (Large Equipment). UL listing is confirmed by the UL output ratings in the specifications. RoHS and REACH documentation is typically provided by ABB for the ACH580 series; confirm with your distributor at RFQ.

MPN
3AXD50000507924