The 3AXD50000751594: The 12.6 A normal-use output (12 A light-overload) is the number that decides motor matching — it's sized for a 5.5 kW induction motor on a 400 V supply. The 380-500 V input range covers standard European and North American three-phase grids; the 47.5-63 Hz frequency tolerance means it handles weak or generator-fed lines without tripping. Frame R1 is the smallest mechanical package in the ACS530 family, so panel space is tight — verify the wall-mount footprint against your enclosure backplate before committing the BOM line.
Integration notes
Wall-mounted, IP20 — plan for a clean, dry cabinet with no condensation. The open-type NEMA enclosure means it's not sealed against dust or hose-down; keep it inside a panel. IE2 efficiency is the baseline for this power class; if your line requires IE3 or IE4 for compliance, this drive won't meet it without a motor upgrade.