Skip to main content
ABB 3AXD50001110079 — AC Drive (VFD) 240V

ABB 3AXD50001110079 ACH180 Micro Drive, 0.75 kW, BACnet

MPN3AXD50001110079
Active

ABB ACH180 series micro drive, order code 3AXD50001110079, 0.75 kW normal-use output, 4.8 A, 200-240 V three-phase, IP20, BACnet communication, frame size R0.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3AXD50001110079 — Electrical Output
ParameterValue
Output power, normal duty (Pn)0.75 kW
Output current, normal duty (In)4.8 A
Output power, heavy duty (PhD)0.55 kW
Output current, heavy duty (IhD)3.2 A
Output power, light-overload duty (PlD)0.75 kW
Output current, light-overload duty (IlD)4.6 A
Output power, heavy duty (UL, Hp)0.75 Hp
Output current, heavy duty (UL)3.7 A
Apparent power output1.9 kV·A
Output power, light-overload duty (UL, Hp)1 Hp
Output current, light-overload duty (UL)4.6 A
Power consumption44 W
3AXD50001110079 — Electrical Input
ParameterValue
Input voltage range200 ... 240 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
Power factor0.98
3AXD50001110079 — Control & I/O
ParameterValue
Digital inputs / outputs4 / 2
Communication protocolBACNET
Analog inputs2
Analog outputs1
Hardware interfacesIndustrial Ethernet 0
3AXD50001110079 — Environmental
ParameterValue
Altitude2000 m
3AXD50001110079 — Mechanical
ParameterValue
Degree of protection (IP)IP20
Enclosure type (NEMA)Open Type
Frame sizeR0
Mounting typeModule

Product details

The ABB 3AXD50001110079 is an ACH180-series micro drive rated for 0.75 kW normal-use output at 4.8 A on a 200-240 V three-phase supply. Heavy-duty use derates to 0.55 kW and 3.2 A — sized for a constant-torque load like a small conveyor or positive-displacement pump. Light-overload use holds at 0.75 kW, 4.6 A, matching the normal-use power but with slightly lower current headroom. UL ratings land at 1 Hp normal-use and light-overload, 0.75 Hp heavy-duty. Built-in BACnet communication makes this drive a direct fit for HVAC building-automation networks — no gateway or protocol converter needed. The 44 W power consumption is the drive's own draw, not the motor load; budget it for panel ventilation and UPS sizing. The drive includes a control unit and mounts as a module in frame size R0. IP20 enclosure means it's for clean indoor panels only — no washdown or dust.

I/O and wiring note

Two analog inputs and one analog output handle speed reference and feedback — 0-10 V or 4-20 mA, jumper-selectable. Four digital inputs and two digital outputs cover start/stop, fault reset, and run-status. No industrial Ethernet interface on this variant; BACnet rides on RS-485, so plan for a serial connection to the BMS controller. Frequency range is 47.5 to 63 Hz, covering 50 Hz and 60 Hz grids without reconfiguration. Power factor of 0.98 is typical for a diode-front-end drive; no active PFC stage, so harmonic content is standard for this class.

Frequently asked questions

What communication protocol does this drive support?

BACnet over RS-485. No industrial Ethernet interface is fitted on this variant.

What is the altitude rating?

Rated for installation up to 2000 m without derating.

What is included with the drive?

The drive includes a control unit. Frame size is R0, module mounting.

MPN
3AXD50001110079