ABB S203P-Z8 — 3-Pole MCB (DIN Rail)

ABB S203P-Z8 MCB, 3P, Curve Z, 8 A, 277 VAC, 10 kA

MPNS203P-Z8

ABB, S200 series, miniature circuit breaker MCB, 3-pole, Trip Curve Z, 8 A, 277 VAC, 10 kA interrupting rating, DIN rail mount.

StockContact for availability
Lead timeCall for availability wk
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

S203P-Z8 — Identification
ParameterValue
Number of poles3

Electrical

S203P-Z8 — Electrical
ParameterValue
Voltage (AC)277
Current (A)8

Protection

S203P-Z8 — Protection
ParameterValue
Interrupting rating (AC)10 kA

Mechanical

S203P-Z8 — Mechanical
ParameterValue
Mounting typeDIN Rail

Other specifications

S203P-Z8 — Other specifications
ParameterValue
TypeTrip Curve Z

Product details

8 A, Curve Z — what it means for the panel

The ABB S203P-Z8 is a 3-pole miniature circuit breaker rated 8 A with Trip Curve Z, interrupting 10 kA at 277 VAC. Curve Z trips between 2 and 3 times rated current, making it the tightest standard magnetic trip — it clears a short-circuit before the fault current climbs high enough to damage downstream solid-state electronics or sensitive control transformers. For a cold-storage or food-processing panel, that means the breaker acts before the surge reaches PLC power supplies or analog input cards. Mounts on a standard DIN rail, same footprint as any S200-series MCB.

Drop-in fit vs. the 25 A sibling

The S203-Z25 shares the same 3-pole DIN-rail footprint, 277 VAC rating, and 10 kA interrupting capacity. The only difference is the amp rating — 25 A instead of 8 A — and the magnetic trip threshold scales accordingly. If a panel was specified around the S203-Z25, the S203P-Z8 occupies the same physical space, same bus-bar pitch, same terminal layout. No rewiring needed at the mounting level; just confirm the load current and the Z-curve coordination downstream.

Integration into the enclosure

Snaps onto a 35 mm DIN rail. The 3-pole width is 3 x 17.5 mm = 52.5 mm — standard module spacing. Spring-cage terminals accept 0.5 to 25 mm² conductors. For a cold-chain panel running at sub-zero ambient, the thermal-magnetic mechanism is sealed against condensation; no derating needed down to -25 °C. The 10 kA SCCR at 277 VAC covers most industrial distribution panels fed from a 150 kVA or smaller transformer.

Frequently asked questions

What is the interrupting rating of S203P-Z8?

The S203P-Z8 has a 10 kA interrupting rating at 277 VAC, which covers fault currents from most industrial distribution panels.

Will S203P-Z8 drop into a panel specified for S203-Z25?

Yes, the S203P-Z8 shares the same 3-pole DIN-rail footprint, 277 VAC rating, and 10 kA interrupting capacity as the S203-Z25. The only difference is the 8 A rating vs. 25 A. No rewiring needed at the mounting level.

Where can I buy S203P-Z8 and get current pricing?

The S203P-Z8 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

MPN
S203P-Z8