ABB S803N-C80 — 3-Pole MCB (DIN Rail)

ABB S803N-C80 MCB S800 3P C 80A, DIN Rail

MPNS803N-C80

ABB S800 series, S803N-C80 MCB, 3-pole, 80 A, Trip Curve C, 230 VAC, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

S803N-C80 — Identification
ParameterValue
Number of poles3
S803N-C80 — Electrical
ParameterValue
Voltage (AC)230
Current (A)80
S803N-C80 — Mechanical
ParameterValue
Mounting typeDIN Rail
S803N-C80 — Other specifications
ParameterValue
TypeTrip Curve C

Product details

The ABB S803N-C80 is a 3-pole miniature circuit breaker from the S800 series, rated 80 A with a Trip Curve C characteristic at 230 VAC.

80 A is the continuous current rating at 230 VAC — sized for a feeder or sub-main branch on a 3-phase system. Trip Curve C means the magnetic trip operates at 5 to 10 times the rated current (400–800 A instantaneous), which suits moderate inrush loads like small motors, transformers, or lighting banks where a short delay before trip avoids nuisance opening on startup. 3-pole construction covers a three-phase circuit; the neutral is handled externally if needed. DIN-rail mounting fits standard 35 mm rail in a distribution board or enclosure — no adapter plate required.

Frequently asked questions

Where can I buy the S803N-C80 and get a price?

The S803N-C80 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the closest functional second-source for the S803N-C80?

The S803S-D63 (63 A, Trip Curve D, 50 kA interrupting) is the closest peer in the S800 series. The main difference is current rating and trip curve — Curve D handles higher inrush, Curve C covers general distribution. The DIN-rail footprint and 3-pole format are identical, so panel fit is the same.

Will the S803N-C80 drop into a panel specified around the S803S-D63?

Yes. Both are 3-pole DIN-rail MCBs from the S800 family with identical mounting and pole count. No rewiring is needed as long as the 80 A rating and Curve C characteristic are correct for the circuit's coordination study.

What is the S803N-C80's listed amps and trip curve?

80 A continuous rating with Trip Curve C (magnetic trip at 5–10× In).

What compliance documentation does ABB provide for the S803N-C80?

ABB typically provides RoHS, REACH, IEC/EN 60898-1, and UL 1077 compliance documentation for the S800 series. Specific certificates should be confirmed at order time.