ABB S803N-D63 — 3-Pole MCB (DIN Rail)

ABB S803N-D63 MCB, 3P D 63 A, DIN Rail

MPNS803N-D63

ABB S800N series, S803N-D63 miniature circuit breaker, 3-pole, Trip Curve D, 63 A, 230 V AC, DIN rail mount.

StockContact for availability
Lead timeCall for availability wk
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

S803N-D63 — Identification
ParameterValue
Number of poles3

Electrical

S803N-D63 — Electrical
ParameterValue
Voltage (AC)230
Current (A)63

Mechanical

S803N-D63 — Mechanical
ParameterValue
Mounting typeDIN Rail

Other specifications

S803N-D63 — Other specifications
ParameterValue
TypeTrip Curve D

Product details

The ABB S803N-D63 is a 3-pole miniature circuit breaker from the S800N series, rated 63 A with a Trip Curve D characteristic at 230 V AC. Curve D provides a higher magnetic trip threshold (typically 10–20× In), making it suited for loads with high inrush currents — motor starters, transformers, or welding equipment — where a B or C curve would nuisance-trip on startup. The DIN-rail footprint drops into standard distribution panels or sub-distribution boards without adapters.

The closest functional peer is the S803S-D63, which shares the same 63 A rating, Trip Curve D, 3 poles, DIN-rail mounting, and 230 V AC voltage. The S803S variant carries a 50 kA interrupting rating versus the S803N's standard rating — a meaningful difference if the available fault current at the panel exceeds the S803N's capability. Both are current-production parts; the choice comes down to the required SCCR for the installation point.

Snap-on DIN-rail mounting for 35 mm rail per EN 60715. The 3-pole block occupies three modular units (17.5 mm per pole). Wire termination accepts copper conductors up to 35 mm²; torque settings for the terminal screws are specified on the side label. The S800N series uses a common busbar system for incoming feed — order the appropriate pin-and-sleeve busbar if paralleling multiple breakers in a group.

Frequently asked questions

What is S803N-D63's listed amps and trip curve?

The S803N-D63 is rated 63 A with a Trip Curve D characteristic. Curve D provides a magnetic trip threshold of 10–20× In, designed for high-inrush loads like motors and transformers.

Will S803N-D63 drop into a panel specified around S803S-D63 without rewiring?

Yes, the S803N-D63 and S803S-D63 share the same 3-pole DIN-rail footprint, 63 A rating, and Trip Curve D. The main difference is interrupting capacity — the S803S is rated 50 kA versus the S803N's standard rating. If the available fault current at the panel is within the S803N's capability, it is a direct mechanical and electrical swap.

Where can I buy S803N-D63 and how is it quoted?

The S803N-D63 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.