ABB 1SAM580000R1004 MS132 Motor Protector, 22-32 A

MPN 1SAM580000R1004

ABB MS132 manual motor protector, rotary handle, 3-pole, order code 1SAM580000R1004, thermal-magnetic, setting range 22 to 32 A, AC-3 15 kW at 400 V, IEC/EN 60947-4-1, UL 508.

$382.00 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

1SAM580000R1004 specifications
ParameterValue
ActuationRotary Handle
VoltageMain Circuit 690 V AC
Insulation voltage ui690 V
Current32 A
FrequencyMain Circuit 50 Hz
Poles3
IP ratingIP20
Temp operating max70 °C
Temp operating min-20 °C
Pollution degree3
Electrical life cycles25000 cycle
Mechanical life cycles50000 cycle
RoHSFollowing EU Directive 2011/65/EU
Setting range22–32 A

Product details

The ABB 1SAM580000R1004 is a 3-pole manual motor protector with a rotary handle, set on the bench between 22 and 32 A by the panel builder before it leaves the shop. At 400 V three-phase it carries AC-3 motors up to 15 kW, with a rated operational current of 32 A and a conventional free-air thermal current of 32 A on the main circuit, which is the figure that actually decides what motor feeder it protects in service.

UL/CSA picture for North American cabinets

On the UL/CSA side the device is listed at 32 A with a maximum operating voltage of 600 V AC on the main circuit, and a 600 V AC general-use rating of 32 A — the cleanest figure for a control-builder doing a UL 508A panel. For three-phase motor loads the horsepower tables give 10 Hp at 200, 208 and 220 to 240 V AC, stepping to 25 Hp between 440 and 480 V AC and continuing through 550 to 600 V AC, which is what the wireman uses to size the feeder rather than the amperage.

Thermal budget and endurance on a cyclic load

Per-pole dissipation runs 3.2 to 6.7 W at the rated operating conditions, so when several protectors are grouped in a row the cabinet ventilation has to clear that local loss on top of the contactor stack next to it. Mechanical durability is 50000 cycles and electrical durability is 25000 cycles, which means on a high-cycling process the protective element — not the handle — will be the first thing to plan a service interval around.

Mounting, wiring and the wireman's bench work

The unit snaps onto a TH35-15 rail per IEC 60715 and is allowed in mounting positions 1 through 6, which removes the usual 'this side up only' fight during retrofits into a crowded back panel. Main-circuit terminations take 2.5 to 50 mm² stranded with a ferrule on the IEC side and 10-2/0 AWG stranded or 10-1/0 AWG on the UL/CSA side, tightened to 4 to 6 N·m (35 to 53 in·lb). The drive uses a 4 mm hex and the strip length is 17 mm on the main circuit.

What the field tech sees during a fault

The rotary handle carries ON / OFF / TRIP indication, so a tripped protector is readable without a laptop or an auxiliary — that is the first thing the night-shift tech checks before pulling covers. Mechanical shock rating is 25g for an 11 ms pulse per IEC 60068-2-27, which covers placement near a stamper or a press without a separate shock-mount bracket.

Compliance trail for the declaration pack

RoHS status is documented as Following EU Directive 2011/65/EU under RoHS information reference 1SAD938506-0050, and the environmental information reference is 1SAA918004-2401, which is what feeds the tech file when the QA reviewer asks for the materials declaration. The instruction manual referenced with the device is 1SAM507001R1001, which is the document the wireman quotes on the test sheet rather than a generic ABB leaflet.