Skip to main content
ABB 1SFA898215R7000

ABB 1SFA898215R7000 PSTX370 Soft Starter, 208-690V AC

MPN 1SFA898215R7000
Active

ABB PSTX370 soft starter, 1SFA898215R7000, auto phase sequence detection, 208-690 V AC, 50/60 Hz, multi-protocol fieldbus.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

1SFA898215R7000 specifications
ParameterValue
Terminal typeMain Circuit: Bars
Voltage208 ... 690 V AC
Frequency50/60 Hz
Temp operating max60 °C
Temp operating min-25 °C

Product details

The ABB 1SFA898215R7000 is a PSTX370 soft starter — the kind of unit you bolt between the contactor and the motor on a pump, fan, or conveyor line to kill the inrush spike. Its headline trick is auto phase sequence detection, meaning it checks the incoming phase rotation before the motor ever sees power, then flags or blocks a wrong hookup. That alone saves a field call when someone swaps a feed and the motor runs backward. Rated for 208 to 690 V AC at 50/60 Hz, with a ramp time adjustable from 1 to 120 seconds. You dial in how fast the motor accelerates — soft enough for a loaded belt, quick enough for a centrifugal pump. Built-in electronic overload protection covers locked rotor, current imbalance, earth fault, and phase reversal.

Fieldbus and control wiring

Communication options cover Modbus RTU/TCP, Ethernet/IP, EtherCAT, DeviceNet, CANopen, Profibus, Profinet, and BACnet (IP and MSTP). That's every common industrial protocol in one terminal — no gateway module needed between this and your PLC rack. Control supply is 100–250 V AC; the control circuit itself runs on 24 V DC. Analog outputs give you 0–10 V, 0–20 mA, or 4–20 mA for feeding motor current or voltage to a drive display or SCADA input. Main circuit terminals are bars — torque them to 25 N·m. Hole diameter is 10.2 mm, so you're looking at cable lugs sized for that stud, not a compression terminal.

The 208–690 V AC operational voltage range covers standard low-voltage motor supplies worldwide — 208 V for North American small motors, 400 V for European IEC networks, 690 V for heavy industrial or mining gear. The 50/60 Hz rating means it works on either line frequency without derating. Ramp time from 1 to 120 seconds gives you the flexibility to match the load's acceleration characteristic. A 1-second ramp is essentially a direct-on-line start; 120 seconds lets you nurse a high-inertia load like a centrifuge or long conveyor up to speed without mechanical shock. Ambient operating temperature of -25 to +60 °C means it lives in unconditioned enclosures — rooftop, desert plant floor, cold storage dock — without a heater or cooler. IP00 on the main terminals means it's open-frame; mount it inside a panel with at least IP54 to keep dust and washdown water off the bus bars.

MPN
1SFA898215R7000