ABB 1SFA898215R7000 PSTX370 Soft Starter, 208-690V AC

MPN1SFA898215R7000
Active

ABB PSTX370 soft starter, 1SFA898215R7000, auto phase sequence detection, 208-690 V AC, 50/60 Hz, multi-protocol fieldbus.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

1SFA898215R7000 key specifications
ParameterValue
Terminal typeMain Circuit: Bars
Product main typePSTX370
Voltage208 ... 690 V AC
Initial voltage during start10 ... 99 %
Step down voltage special ramp100 ... 10 %
Rated control supply voltage100 ... 250 V AC
Rated control circuit voltage24 V DC
Technical UL (CSA, maximum operating voltage UL, CSA)Main Circuit 690 V
Current limit function1.5 ... 7.5 xle
Starting capacity at maximum rated current ie4xIe for 10s
Rated operational current - In-Line connection370 A
Rated operational current - inside delta connection640 A

All specifications

1SFA898215R7000 additional specifications
ParameterValue
Technical UL (CSA, horsepower rating UL, CSA)(200 ... 208 V AC) Three Phase 125 Hp
Rated operational power - In-Line connection(230 V) 110 kW
Rated operational power - inside delta connectionat 230 V 200 kW
Rated frequency50/60 Hz
IP ratingacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
ProtocolModbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
Switch for inside delta connectionYes
Popular downloads (CAD dimensional drawing)2CDC001079B0201
Material compliance (Toxic substances control act - TSCA)2CMT2023-006524
Material compliance (Conflict minerals reporting template)9AKK108467A5658
Technical UL (CSA, tightening torque UL, CSA)Main Circuit 221.3
FunctionAuto phase sequence detection
Ramp time1 ... 120 second [unit of time]
Analog outputs0...10 V, 0...20 mA, 4...20 mA
Warning detailsCurrent imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Run signal relayYes
Tightening torqueMain Circuit 25 N·m
Fault signal relayYes
Overload protectionBuilt-in electronic overload protection
Protection functionBypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
By-pass signal relayYes
Overload signal relayYes
Ambient air temperatureOperation -25 ... +60 °C
Service factor percentage100 %
Object classification codeQ
Popular downloads (EPLAN data)9AAC181171_EPLAN
Signal indication faultRed
Integrated electronic overloadYes
Connecting capacity main circuitHole Diameter 10.2 mm
Signal indication running rGreen
Connecting capacity supply circuitRigid 1 x 2.5
IDEA granular category code4740 >> Soft starter
Signal indication protectionYellow
Connecting capacity control circuitRigid 1 x 2.5 mm²
Popular downloads (Instructions and manuals)1SFC132428M0201
Popular downloads (Data sheet, technical information)1SFC132012C0201
Popular Downloads/Instructions and manuals (Part 2)1SFC132081M0201
Popular Downloads/Instructions and manuals (Part 3)1SFC132060M0201

Product details

The ABB 1SFA898215R7000 is a PSTX370 soft starter — the kind of unit you bolt between the contactor and the motor on a pump, fan, or conveyor line to kill the inrush spike. Its headline trick is auto phase sequence detection, meaning it checks the incoming phase rotation before the motor ever sees power, then flags or blocks a wrong hookup. That alone saves a field call when someone swaps a feed and the motor runs backward. Rated for 208 to 690 V AC at 50/60 Hz, with a ramp time adjustable from 1 to 120 seconds. You dial in how fast the motor accelerates — soft enough for a loaded belt, quick enough for a centrifugal pump. Built-in electronic overload protection covers locked rotor, current imbalance, earth fault, and phase reversal.

Fieldbus and control wiring

Communication options cover Modbus RTU/TCP, Ethernet/IP, EtherCAT, DeviceNet, CANopen, Profibus, Profinet, and BACnet (IP and MSTP). That's every common industrial protocol in one terminal — no gateway module needed between this and your PLC rack. Control supply is 100–250 V AC; the control circuit itself runs on 24 V DC. Analog outputs give you 0–10 V, 0–20 mA, or 4–20 mA for feeding motor current or voltage to a drive display or SCADA input. Main circuit terminals are bars — torque them to 25 N·m. Hole diameter is 10.2 mm, so you're looking at cable lugs sized for that stud, not a compression terminal.

The 208–690 V AC operational voltage range covers standard low-voltage motor supplies worldwide — 208 V for North American small motors, 400 V for European IEC networks, 690 V for heavy industrial or mining gear. The 50/60 Hz rating means it works on either line frequency without derating. Ramp time from 1 to 120 seconds gives you the flexibility to match the load's acceleration characteristic. A 1-second ramp is essentially a direct-on-line start; 120 seconds lets you nurse a high-inertia load like a centrifuge or long conveyor up to speed without mechanical shock. Ambient operating temperature of -25 to +60 °C means it lives in unconditioned enclosures — rooftop, desert plant floor, cold storage dock — without a heater or cooler. IP00 on the main terminals means it's open-frame; mount it inside a panel with at least IP54 to keep dust and washdown water off the bus bars.

Frequently asked questions

What is the function of 1SFA898215R7000?

Its primary listed function is auto phase sequence detection — it verifies the incoming phase rotation before the motor starts and can block or warn on a reversed phase.

What protocols does the fieldbus support?

Modbus RTU, Modbus TCP, Ethernet/IP, EtherCAT, DeviceNet, CANopen, Profibus, Profinet, BACnet IP, and BACnet MSTP. No external gateway needed for any of them.

What protection functions are built in?

Electronic overload, locked rotor, current imbalance, earth fault, phase reversal, under/over voltage, PTC and PT-100 thermistor inputs, and user-defined protection. The overload is integrated — no separate relay required.