Skip to main content
Schneider Electric A9C62363

A9C62363 Reflex iC60N, 63 A 3P curve C integrated control MC

MPN A9C62363
Obsolete

Schneider Electric Acti9 Reflex iC60N integrated control circuit breaker, A9C62363, 63 A, 3P, curve C, thermal-magnetic trip, 20 kA breaking capacity.

$413.29 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9C62363 specifications
ParameterValue
Trip unit typeThermal-magnetic
Main product or component typeIntegrated control circuit breaker
Coil voltage230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC
Insulation voltage ui500 V AC
Breaking capacity20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
IP ratingIP20
Pollution degree3
ColorWhite
Depth77 mm
Width99 mm
Height84 mm
Electrical life cyclesAC-1: 50000 cycles AC 50 Hz
Mechanical life cycles50000 cycles
ApplicationDistribution Control

Product details

It is rated 63 A with a C trip curve, meaning it handles moderate inrush from motor or lighting loads without nuisance tripping, and clears faults up to 20 kA at 230 V AC (10 kA at 415 V AC) per EN/IEC 60947-2. For a 63 A breaker, that means magnetic pickup between 315 A and 630 A — typical for general distribution and control circuits feeding multiple loads. Control is via a 230 V AC or 24 V AC/DC coil (also 48 V AC/DC), accepting maintained, impulse, or maintained very-low-voltage signals. A flashing LED indicates tripped, overheat, or ready status; a red LED flags faults; green shows the device is ON. The breaker is padlockable in the OFF position.

The 3P footprint fits standard distribution board spacing. Designed for distribution and control applications — think sub-distribution boards, lighting control panels, or small motor control centers where you need both overcurrent protection and remote ON/OFF capability without a separate contactor and MCB stack.

Rated for 50,000 electrical cycles (AC-1) and 50,000 mechanical cycles, which is solid for a panel component that sees daily switching. The electrical durability figure matters if you are cycling it under resistive load; derate for inductive loads per the AC-3 curve if driving motors directly.

MPN
A9C62363