Schneider Electric A9D37220

Schneider Electric A9D37220 Acti9 iC60 RCBO, 20 A, 30 mA, Ty

MPN A9D37220
Active

Schneider Electric Acti9 iC60 RCBO, A9D37220, 2P, 20 A, 30 mA, curve B, 10 kA Icn, DIN rail clip-on.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9D37220 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage220...240 V AC 50 Hz
Insulation voltage ui500 V AC 50 Hz
Breaking capacity10000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 15 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2
Terminal pitch9 mm between poles
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
ColorWhite

All specifications

A9D37220 additional specifications
ParameterValue
Depth78 mm
Width36 mm
Height86 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric A9D37220 is a 2-pole Acti9 iC60 RCBO — a combined residual-current circuit breaker with overcurrent protection (RCBO) rated 20 A, 30 mA sensitivity, curve B, for 50 Hz AC networks.

The 20 A thermal-magnetic trip (curve B, magnetic threshold 3–5 × In) is sized for resistive and light inductive loads on a final subcircuit — lighting, general sockets, small appliances. The 30 mA earth-leakage sensitivity meets standard personnel protection requirements (IEC 60364). Breaking capacity is 10 kA Icn per EN/IEC 61009-2-1 at 220–240 V AC, with an ultimate Icu of 15 kA per EN/IEC 60947-2 — sufficient for most residential and light commercial distribution boards where the prospective fault current stays under that ceiling. Limitation class 3 (EN/IEC 61009-2-1) means it limits let-through energy under fault conditions, reducing stress on downstream wiring and connected equipment. The 2-pole RCBO protects both poles against overcurrent and earth leakage; the neutral is switched and monitored internally.

Mounts via clip-on to a DIN rail (EN 60715). Occupies 4 × 9 mm pitches = 36 mm width. Tunnel terminals accept 1–35 mm² rigid or 1–25 mm² flexible cable; strip 12 mm, tighten to 2 N·m. Connection pitch is 9 mm between poles — standard for modular DIN-rail devices. IP40 in a distribution enclosure, IP20 bare. The toggle provides ON/OFF and fault-trip local signalling.