Skip to main content
Schneider Electric A9D37625

Schneider Electric A9D37625 Acti9 iDPN Vigi RCBO, 25A C-curv

MPN A9D37625
Active

Schneider Electric Acti9 iDPN Vigi, RCBO, 1P+N, 25 A, C-curve, 30 mA earth-leakage, 10 kA breaking capacity, DIN rail clip-on.

$59.50 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9D37625 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage230...240 V AC 50 Hz
Insulation voltage ui400 V AC 50 Hz
Breaking capacity10000 A Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Terminal pitch9 mm between phase and neutral
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3

All specifications

A9D37625 additional specifications
ParameterValue
ColorWhite
Depth73 mm
Width36 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric A9D37625 is an Acti9 iDPN Vigi residual-current circuit breaker with overcurrent protection (RCBO), combining a 25 A thermal-magnetic trip (C-curve, 5–10× In magnetic threshold) with integrated 30 mA earth-leakage protection in a single 1P+N module.

The 25 A rated current (In) governs the continuous load the RCBO can carry without tripping on thermal overload — sized for a 25 A feeder or final circuit. The 30 mA earth-leakage sensitivity provides personal protection against direct contact (30 mA is the standard threshold for shock protection per IEC 60364). The 10 kA Icn breaking capacity at 230–240 V AC 50 Hz tells you this RCBO can safely interrupt a fault current up to 10 kA without welding contacts or failing — that's the standard domestic/commercial rating for most European distribution boards; if your prospective fault current exceeds 10 kA, you need a current-limiting upstream device or a higher-rated breaker.

This is an outgoer device — it protects the final circuit, not the incoming supply. Clip it onto a DIN rail (EN 60715) inside an Acti9 enclosure or any standard modular distribution board. The 9 mm pitch between phase and neutral matches the Acti9 busbar system, so you can feed it from a common busbar without extra wiring.

MPN
A9D37625