Schneider Electric A9D47606 Acti9 iDPN Vigi 6A C-curve RCBO,

MPN A9D47606
Obsolete

Schneider Electric Acti9 iDPN Vigi, RCBO, 1P+N, 6 A, C-curve, 10 kA Icn, 300 mA earth leakage, DIN rail clip-on.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9D47606 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage230...240 V AC 50 Hz
Insulation voltage ui400 V AC 50 Hz
Breaking capacity10000 A Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Terminal pitch9 mm between phase and neutral
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3

All specifications

A9D47606 additional specifications
ParameterValue
ColorWhite
Depth73 mm
Width36 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

Rated 6 A with a C-curve trip characteristic and 10 kA breaking capacity at 230...240 V AC, it protects a single-phase final subcircuit against overload, short-circuit, and earth leakage (300 mA sensitivity) in one package. The thermal-magnetic trip unit handles the overcurrent side; the integrated earth-leakage module covers the ground-fault protection.

The 6 A rating limits the continuous load to lighting or small socket circuits; the C-curve (magnetic trip at 5-10 x In, so 30-60 A instantaneous) suits moderate inrush loads like fluorescent banks or small motors. The 300 mA earth-leakage sensitivity is a delayed or high-threshold residual-current setting — not a 30 mA personal-protection level. It is intended for equipment protection or fire-prevention on circuits where nuisance tripping from leakage in permanently connected equipment (water heaters, computers, HVAC) would be unacceptable. The integrated RCD module means no separate earth-leakage device is needed in the same DIN-rail row, saving one module width.

IP20 finger-safe terminals (IP40 inside the modular enclosure) suit enclosed distribution boards; not rated for wet or dusty environments. The toggle gives local ON/OFF/fault-trip indication, useful for troubleshooting without a meter.