Schneider Electric A9D53613

Schneider Electric A9D53613 Acti9 iDPN Vigi RCBO, 13 A, 30 m

MPN A9D53613
Obsolete

Schneider Electric Acti9 iDPN Vigi RCBO, 1P+N, 13 A, C-curve, 30 mA earth leakage, 6 kA breaking capacity, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9D53613 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage230...240 V AC 50 Hz
Insulation voltage ui400 V AC 50 Hz
Breaking capacity6000 A Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Terminal pitch9 mm between phase and neutral
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3

All specifications

A9D53613 additional specifications
ParameterValue
ColorWhite
Depth73 mm
Width36 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric A9D53613 is an Acti9 iDPN Vigi residual-current circuit breaker with overcurrent protection (RCBO) — one compact unit that combines a 13 A thermal-magnetic MCB and a 30 mA earth-leakage module. It protects a single-phase final subcircuit (1 pole + neutral) against overload, short-circuit, and earth faults, all in a 36 mm wide (4 x 9 mm pitch) clip-on module that snaps onto a DIN rail inside a distribution board.

Rated 13 A (In) with a C-curve magnetic trip (5 to 10 x In), so it's sized for general-purpose loads like lighting, socket outlets, and small appliances where inrush current is moderate — not for motor starting or transformer loads that need a D-curve. The 30 mA earth-leakage sensitivity (IΔn) meets the standard for personal protection in residential and commercial final circuits; it will trip on a fault current above 30 mA between live and earth. Breaking capacity is 6 kA Icn at 230…240 V AC, 50 Hz, conforming to EN/IEC 61009-2-1 — that's the maximum fault current the device can safely interrupt.

Clip-on mounting to DIN rail, 36 mm wide (4 x 9 mm pitches). Terminals accept 1…16 mm² rigid or 1…10 mm² flexible wire, with a stripping length of 15 mm and a tightening torque of 2 N·m. IP20 on the front, IP40 inside the modular enclosure.

MPN