Schneider Electric A9D55720

Schneider Electric A9D55720 Acti9 DPN Vigi RCBO, 20 A, 30 mA

MPN A9D55720
Obsolete

Schneider Electric Acti9 DPN Vigi RCBO, A9D55720, 20 A, 30 mA, Curve B, 6 kA, 3P+N, DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9D55720 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage380...415 V AC 50/60 Hz
Insulation voltage ui440 V AC 50/60 Hz
Breaking capacity6000 A Icn at 380...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Temp storage max70 °C
Temp storage min-30 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-30...70 °C
Pollution degree3
ColorWhite

All specifications

A9D55720 additional specifications
ParameterValue
Depth78.5 mm
Width90 mm
Height91 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-5...60 °C

Product details

The Schneider Electric A9D55720 is a 20 A, 30 mA residual current circuit breaker with overcurrent protection (RCBO) from the Acti9 DPN Vigi range, combining a Curve B MCB and an RCD in a single 3P+N module. The 20 A rated current (In) governs the continuous load it can carry in a distribution board — sized for lighting, general-purpose socket circuits, or small motor loads where the full-load current stays under 16 A for headroom. The 30 mA earth-leakage sensitivity provides personnel protection against direct contact, compliant with the requirements of IEC 60364 for final circuits in residential and commercial installations. Curve B (magnetic trip at 3 to 5 x In, so 60 to 100 A) suits predominantly resistive loads or short cable runs where inrush is low — common for lighting and socket-outlet circuits where the MCB should not nuisance-trip on a cold filament or capacitor bank. The 6 kA breaking capacity (Icn at 380...415 V AC, 50/60 Hz) is the maximum prospective fault current the device can safely interrupt under standard test conditions per EN/IEC 61009-2-1. The limitation class 3 (energy let-through) means it restricts the I²t pass-through energy, helping with downstream coordination and reducing arc-flash stress on the connected wiring.