Skip to main content
Schneider Electric A9D56606

Schneider Electric A9D56606 Acti9 iDPN Vigi RCBO, 6A B-Curve

MPN A9D56606
Obsolete

Schneider Electric Acti9 iDPN Vigi RCBO, 1P+N, 6 A, B-curve, 30 mA earth leakage, 6000 A Icn, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9D56606 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage230...240 V AC 50 Hz
Insulation voltage ui400 V AC 50 Hz
Breaking capacity6000 A Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Terminal pitch9 mm between phase and neutral
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3

All specifications

A9D56606 additional specifications
ParameterValue
ColorWhite
Depth73 mm
Width36 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The 6000 A Icn breaking capacity at 230...240 V AC 50 Hz, compliant with EN/IEC 61009-2-1, means this RCBO can safely interrupt fault currents up to that level without welding its contacts or cascading failure upstream — sufficient for most residential and light commercial final circuits where the prospective short-circuit current stays under that threshold.

The B-curve (magnetic tripping limit 3...5 x In) means the device trips instantaneously between 18 A and 30 A — suited for resistive and general-purpose loads with low inrush, such as lighting circuits, socket outlets, and small control transformers. The 30 mA residual sensitivity provides personal protection against direct contact faults, compliant with IEC 60364 requirements for socket-outlet circuits. Thermal-magnetic trip technology combines a bimetal strip for overload protection and a solenoid for short-circuit detection, giving a time-current curve that coordinates with downstream MCBs and upstream fuses.

Installation and wiring

Terminals accept 1...16 mm² rigid or 1...10 mm² flexible conductors; strip length 15 mm, tightening torque 2 N.m. The toggle provides local ON/OFF/fault-trip signalling. Electrical and mechanical durability are both rated at 20,000 cycles.

MPN