Skip to main content
Schneider Electric A9D87425

Schneider Electric A9D87425 Acti9 iC60 RCBO, 25 A, 4P, 30 mA

MPN A9D87425
Active

Schneider Electric Acti9 iC60 RCBO, 4P, 25 A, curve B, 30 mA earth-leakage sensitivity, 6 kA breaking capacity, DIN-rail mount, white.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9D87425 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage380...415 V AC 50 Hz
Insulation voltage ui500 V AC 50 Hz
Breaking capacity6000 A Icn at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1 6 kA Icu at 380...415 V AC 50 Hz conforming to EN/IEC 60947-2
Terminal pitch9 mm between poles
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
ColorWhite

All specifications

A9D87425 additional specifications
ParameterValue
Depth78 mm
Width72 mm
Height86 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The A9D87425 is a 4-pole Acti9 iC60 RCBO (residual-current circuit breaker with overcurrent protection) rated 25 A with a B curve — magnetic tripping between 3 and 5 times In, so it clears short-circuit faults quickly on resistive or general-purpose loads without nuisance trips from inrush. The 30 mA earth-leakage sensitivity provides personnel protection against direct contact, meeting the standard for socket-outlet circuits in residential and commercial distribution boards. Breaking capacity is 6 kA Icu at 380–415 V AC 50 Hz per EN/IEC 60947-2, which means it safely interrupts a fault current up to that level without welding contacts or cascading upstream — sized for most sub-distribution panels where the prospective short-circuit current stays under 6 kA. The thermal-magnetic trip unit combines a bimetal strip for overload protection (time-delayed) and a solenoid for short-circuit protection (instantaneous). The B curve holds the magnetic trip threshold at 3–5× In, so a 25 A unit trips magnetically between 75 A and 125 A — a good match for lighting, socket outlets, and control circuits where the load doesn't draw a heavy starting surge.

Clip-on mounting onto a DIN rail — 8 pitches of 9 mm between poles, so the 4-pole unit occupies 72 mm of rail width. Height is 86 mm, depth 78 mm. Local signalling on the toggle shows ON, OFF, and fault-trip positions — no need to guess whether the device tripped on overcurrent or earth leakage. The fault-trip indication is mechanical, so it works even without auxiliary contacts.

MPN
A9D87425