Skip to main content
Schneider Electric A9DC7610

A9DC7610 Acti9 iCV40 RCBO, 10 A, 30 mA, Type AC, 6 kA

MPN A9DC7610
Active

Schneider Electric Acti9 iCV40 RCBO, A9DC7610, 1P+N, 10 A, C-curve, 300 mA earth-leakage, 6 kA Icn, DIN-rail mount.

$232.74 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9DC7610 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage230 V AC 50/60 Hz
Insulation voltage ui400 V AC 50/60 Hz
Breaking capacity6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Terminal pitch9 mm between phase and neutral
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3

All specifications

A9DC7610 additional specifications
ParameterValue
ColorWhite
Depth73 mm
Width36 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The C-curve (5–10 x In) means the magnetic trip holds through motor inrush and capacitive loads that would nuisance-trip a B-curve; expect it to pass a 10 A lighting or small-appliance circuit without false trips. Integrated earth-leakage protection at 300 mA sensitivity (Type AC, per the device class) covers cable insulation faults and gradual leakage. This is not a 30 mA personal-protection device — it is sized for equipment protection and fire prevention on circuits where a lower threshold would cause nuisance tripping from natural leakage. Limitation class 3 (EN/IEC 61009-2-1) means the device limits let-through energy under fault conditions, reducing stress on downstream wiring and connected equipment.

Clip-on mounting to DIN rail (35 mm per EN 60715) with a 9 mm pitch between phase and neutral terminals. Neutral is on the left, phase on the right — wire accordingly. Tunnel terminals accept 1–16 mm² rigid or 1–10 mm² flexible; strip 14 mm and torque to 2 N·m. The white colour is standard for the Acti9 range. Local ON/OFF and fault indication (mechanical flag) helps a field tech identify a tripped RCBO without metering.

MPN
A9DC7610