Skip to main content
Schneider Electric A9DF3725

Schneider Electric A9DF3725 Acti9 iCV40 RCBO, 25 A C-curve 3

MPN A9DF3725
Active

Schneider Electric Acti9 iCV40 RCBO, A9DF3725, 25 A, C-curve, 30 mA earth leakage, 6 kA breaking capacity, 3P+N, DIN rail.

$281.23 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9DF3725 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage400 V AC 50/60 Hz
Insulation voltage ui440 V AC 50/60 Hz
Breaking capacity6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3
ColorWhite

All specifications

A9DF3725 additional specifications
ParameterValue
Depth73 mm
Width90 mm
Height93 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric A9DF3725 is an Acti9 iCV40 residual-current circuit breaker with overcurrent protection (RCBO) — a single module that combines a 25 A thermal-magnetic MCB with a 30 mA earth-leakage detector in a 3P+N, 4-module-wide package.

The 3P+N unit occupies 10 × 9 mm pitches (90 mm width) on a DIN rail, with a depth of 73 mm and height of 93 mm. The neutral is on the left; the connection pitch is 18 mm between phases and 9 mm between phase and neutral — standard for Acti9 modular enclosures. Tunnel terminals accept 1–16 mm² rigid or 1–10 mm² flexible cable; strip length is 14 mm, torque to 2 N·m.

For a BOM freeze or a line-down replacement, the spec is fixed: 25 A rated current, 30 mA earth-leakage sensitivity, C-curve, 3P+N, 6 kA at 400 V AC. No second-source cross-reference exists within the Acti9 family at this exact rating combination — the iCV40N (device short name) is the only variant with these parameters.

Durability and environmental limits

Rated for 20,000 electrical and 20,000 mechanical cycles — consistent with a distribution-grade RCBO for frequent switching under load. Operating altitude is 2000 m; relative humidity tolerance is 95% at 55 °C, which covers most non-condensing indoor environments.

MPN