Schneider Electric A9DF7640 Acti9 iCV40 40A RCBO, 6kA, 300mA

MPN A9DF7640
Active

Schneider Electric Acti9 iCV40N RCBO, 1P+N, 40 A, C-curve, 6 kA breaking capacity, 300 mA earth-leakage, DIN-rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9DF7640 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage230 V AC 50/60 Hz
Insulation voltage ui400 V AC 50/60 Hz
Breaking capacity6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Terminal pitch9 mm between phase and neutral
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3

All specifications

A9DF7640 additional specifications
ParameterValue
ColorWhite
Depth73 mm
Width36 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric A9DF7640 is an Acti9 iCV40N residual-current circuit breaker with overcurrent protection (RCBO), combining a 40 A thermal-magnetic MCB and a 300 mA earth-leakage module in a single 36 mm wide, 1P+N package.

The unit's breaking capacity is 6000 A Icn at 230 V AC, tested to EN/IEC 61009-2-1. For coordination, the limitation class is 3 per the same standard, meaning it lets through less energy than a class-3 threshold, which helps the upstream breaker stay selective on a hard fault.

Earth-leakage and trip technology

The integrated earth-leakage protection is set at 300 mA sensitivity — that's a common level for general distribution circuits where you want to guard against insulation faults but avoid nuisance tripping from normal leakage on long cable runs or equipment with filters. The trip unit is thermal-magnetic: the thermal bimetal handles overloads (slow, inverse-time), and the solenoid handles short-circuits (instantaneous above the magnetic threshold). Both the overcurrent and residual-current functions are in one housing, so it saves a DIN-rail position compared to a separate MCB and RCCB.

Installation and wiring details

Torque them to 2 N·m, and strip 14 mm of insulation. The toggle gives local ON/OFF and fault indication, which is handy for a maintenance electrician tracing a tripped circuit without pulling the front cover.