Schneider Electric A9DG2606

Schneider Electric A9DG2606 Acti9 iCV40 6A B-Curve RCBO, 30m

MPN A9DG2606
Active

Schneider Electric Acti9 iCV40 RCBO, A9DG2606, 1P+N, 6 A, B-curve, 30 mA earth leakage, 4.5 kA breaking capacity.

$202.23 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9DG2606 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage230 V AC 50/60 Hz
Insulation voltage ui400 V AC 50/60 Hz
Breaking capacity4500 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Terminal pitch9 mm between phase and neutral
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3

All specifications

A9DG2606 additional specifications
ParameterValue
ColorWhite
Depth73 mm
Width36 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

What this RCBO does and why it matters for your panel

The Schneider Electric A9DG2606 is an Acti9 iCV40 RCBO — a combined overcurrent and earth-leakage protection device in a 1P+N format, rated 6 A with a B-curve trip characteristic and 30 mA residual-current sensitivity.

Breaking capacity is 4500 A Icn at 230 V AC, 50/60 Hz, per EN/IEC 61009-2-1. The limitation class is 3, meaning it limits let-through energy under fault conditions, reducing stress on downstream wiring and equipment. The thermal-magnetic trip unit combines a bimetal strip for overload protection (time-delayed, inversely proportional to current) and a solenoid for short-circuit protection (instantaneous above the magnetic threshold). The magnetic tripping limit of 3–5 x In means for a 6 A device, it trips instantaneously between 18 A and 30 A — typical for B-curve coordination with cable protection. Integrated earth-leakage protection at 30 mA sensitivity covers both sinusoidal AC residual currents (Type AC, implied by the AC network designation) and meets the standard requirement for socket-outlet circuits in many IEC-based wiring regulations.

Mounting and wiring — what fits where

Clip-on mounting to a 35 mm DIN rail, with tunnel-type terminals accepting 1–16 mm² rigid or 1–10 mm² flexible conductors. The 9 mm connection pitch between phase and neutral matches standard Acti9 busbar systems, so it integrates directly into a Schneider distribution board without adaptors.