Skip to main content
Schneider Electric A9DG2610

Schneider Electric A9DG2610 Acti9 iCV40 RCBO, 10A B Curve 30

MPN A9DG2610
Active

Schneider Electric Acti9 iCV40 RCBO, A9DG2610, 1P+N, 10 A, B curve, 30 mA earth leakage, 4.5 kA breaking capacity, DIN rail mount.

$202.23 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9DG2610 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage230 V AC 50/60 Hz
Insulation voltage ui400 V AC 50/60 Hz
Breaking capacity4500 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Terminal pitch9 mm between phase and neutral
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3

All specifications

A9DG2610 additional specifications
ParameterValue
ColorWhite
Depth73 mm
Width36 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The integrated 30 mA earth-leakage protection means it covers both overload/short-circuit and ground-fault detection in one DIN-rail unit, saving a module width versus separate MCB + RCD. Breaking capacity is 4.5 kA Icn at 230 V AC, 50/60 Hz, conforming to EN/IEC 61009-2-1 — adequate for residential and light commercial sub-distribution boards where the prospective fault current stays under that threshold. Thermal-magnetic trip technology gives a time-delayed thermal response for overloads and an instantaneous magnetic response for shorts. Limitation class 3 means the device limits let-through energy in a fault — relevant for downstream cable protection and coordination with upstream devices.

Clip-on mounting to a DIN rail, 36 mm width (4 x 9 mm pitches), 85 mm height, 73 mm depth. Tunnel-type terminals accept 1 to 16 mm² rigid or 1 to 10 mm² flexible cable; strip length 14 mm, tightening torque 2 N·m. IP20 on the front face, IP40 inside the modular enclosure — standard for distribution boards.

Certified to EN/IEC 61009-2-1 with KEMA-KEUR and VDE quality marks. Electrical durability 20,000 cycles, mechanical durability 20,000 cycles. Local signalling provides ON/OFF indication and fault indication on the toggle.

MPN
A9DG2610