Skip to main content
Schneider Electric A9F03650

Schneider Electric A9F03650 Acti9 iC60N MCB, 50 A, 1P+N, B C

MPN A9F03650
Obsolete

Schneider Electric Acti9 iC60N, miniature circuit breaker, A9F03650, 50 A, 1P+N, B curve, 36 kA Icu, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F03650 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F03650 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F03650 is an Acti9 iC60N miniature circuit breaker rated 50 A with a B curve, 1P+N configuration. The 36 kA Icu at 12…60 V AC (EN/IEC 60947-2) tells you it can safely interrupt a fault up to that level without failing; the 6 kA Icn at 230 V (EN/IEC 60898-1) is the domestic-grade rating for the same part. That dual-standard listing (60947-2 for industrial, 60898-1 for residential) means it qualifies for either panel type, which simplifies BOM management. The 1P+N pole arrangement switches the line and disconnects the neutral, protecting one pole. The neutral position is left, so it lands predictably on the DIN rail in a standard distribution board. Thermal-magnetic trip technology covers both overload (thermal bimetal) and short-circuit (magnetic solenoid) — no electronics to fail, no auxiliary power needed.

Mounts on a DIN rail — standard snap-on fit for any enclosure. Takes 4 module pitches (36 mm width), so it occupies four 9 mm slots in the board. Height is 91 mm, depth 78.5 mm — check your enclosure door clearance if you're fitting a cover or gland plate.

Pollution degree 3, overvoltage category IV, tropicalisation class 2 per IEC 60068-1 (handles 95 % RH at 55 °C). The part carries a trip indicator and contact position indicator for visual status at the panel.

MPN